MicroDock II

Installation

a

Warning

The atmosphere must be free of background gas. Do not
use the base station in a hazardous area.
All required National Electrical Codes (NEC) and safety
standards must be followed.

Note

The base station can operate from either an electrical
power source or batteries. The batteries will provide
automatic backup power if the main power fails.

1.

Connect the power cord to the POWER port on the
base station, and then plug the cord into an AC outlet.

To install the batteries, refer to

Battery Installation

.

2.

Connect the charger cord to the CHARGER port on
the base station first, and then plug the cord into an
AC outlet.

3.

Attach all gas connections. Inlet 1 (PURGE) is config-
ured for ambient air and inlets 2-5 are configured for
calibration/test gases. Refer to

Confirm Inlet Setup

.

4.

A demand flow regulator must be used with all gas
cylinder connections.

5.

Ensure the exhaust line is not connected to a nega-
tive pressure system.

For AC main installation, a circuit breaker must be integrated in the
building installation as a disconnect device for the base station.

The disconnect device must be installed in close proximity to
the base station and must be marked as a disconnecting
method for the base station.

Battery Installation

To install batteries in the base station, complete the following:

a

Warning

Only install batteries in a safe area that is free of
hazardous gas. Failure to adhere to this warning can
result in personal injury and/or property damage.
Use only BW approved batteries; do not use alkaline or
other rechargeable batteries with this charger.

1.

Loosen the retaining screws from the battery cover.
Do not remove the screws from the cover.

2.

Remove the battery cover and insert four C-cell bat-
teries into the battery compartment.

3.

Replace the battery cover and tighten the retaining
screws. Do not overtighten.