CALIBRATION INSTRUCTIONS

CALIBRATION INSTRUCTIONS

CALIBRATION INSTRUCTIONS

CALIBRATION INSTRUCTIONS

The spreader was factory calibrated, however, calibration should be checked occasionally to
assure optimum performance.

1.

Pull the on/off lever to the “OFF” position.

Set the rate control plate to setting “B”.

3.

Loosen the rate control knob and slide the rate

plate until the port is just opening. Loosen
pointer screw and move pointer until it aligns
with “B” on the rate plate. Retighten pointer
screw.

2.

Flip on/off control lever to the “ON” position.

Check the port opening. It should be just open.
If adjustment is necessary, continue to step #3.

Rate Control Knob

Pointer

Rate Control Plate

Port is just open

Pointer Screw

VIEW IS

INSIDE OF

HOPPER