Codabar, Codabar -3, Codabar on/off codabar start/stop characters – Honeywell XENON 1902 User Manual

Page 145: Codabar check character

Advertising
background image

7 - 3

Codabar

<Default All Codabar Settings>

Codabar On/Off

Codabar Start/Stop Characters

Start/Stop characters identify the leading and trailing ends of the bar code.
You may either transmit, or not transmit Start/Stop characters.
Default = Don’t Transmit.

Codabar Check Character

Codabar check characters are created using different “modulos.” You can
program the scanner to read only Codabar bar codes with Modulo 16 check
characters.

Default = No Check Character.

No Check Character indicates that the scanner reads and transmits bar
code data with or without a check character.

When Check Character is set to

Validate and Transmit, the scanner will

only read Codabar bar codes printed with a check character, and will trans-
mit this character at the end of the scanned data.

* On

Off

Transmit

* Don’t Transmit

Advertising
This manual is related to the following products: