Rs232 serial port, Rs485, Rs232 serial port -2 rs485 -2 – Honeywell XENON 1902 User Manual

Page 36: R to

Advertising
background image

2 - 2

RS232 Serial Port

The RS232 Interface bar code is used when connecting to the serial port
of a PC or terminal. The following RS232 Interface bar code also pro-
grams a carriage return (CR) and a line feed (LF) suffix, baud rate, and
data format as indicated below. It also changes the trigger mode to man-
ual.

RS485

Scan one of the following “Plug and Play” codes to program the scanner for
an IBM POS terminal interface.

Note: After scanning one of these codes, you must power cycle the cash

register.

Option

Setting

Baud Rate

115,200 bps

Data Format

8 data bits, no parity bit, 1 stop bit

RS232 Interface

IBM Port 5B Interface

IBM Port 9B

HHBCR-1 Interface

IBM Port 17 Interface

IBM Port 9B

HHBCR-2 Interface

Advertising