Flexible Power Management

If you are experiencing network performance issues, and suspect the scanner is
interfering with other devices, you can turn down the power output of the scan-
ner. This reduces the range between the scanner and a base or an Access
Point as shown in the following illustration:

Scan one of the bar codes below to set the scanner’s power output to Full
Power
(100%) [2.5mW, 4dBm], Medium Power (35%) [.875mW, 0dBm],
Medium Low Power (5%) [.125mW, -9dBm], or Low Power (1%, .025mW,
-16dBm).

Default = Full Power.

For the new power setting to take effect, the scanner and the base or Access
Point must be reset. See

Reset Scanner and Base/Access Point

(page 3-

16).

Full Power

Reduced Power

1902

Scanner

802.11

LAN

* Full Power

Medium Power

Medium Low Power

Low Power