Auto Reconnect Mode

Auto Reconnect controls whether or not the scanner automatically begins
the relink process when a loss of connection is detected. When the Auto
Reconnect On
bar code is scanned, the scanner begins the relink process
immediately, without user intervention.

Default = Auto Reconnect On.

Note: If you are connecting to a Bluetooth Interface Module, set Auto

Reconnect to Off.

The table below shows the results of the Auto Reconnect On and Off set-
tings:

Event

Auto Reconnect On

Auto Reconnect Off

Scanner out of
range

Relink occurs
automatically. If
maximum number of link
attempts is
unsuccessful, then the
scanner must be
relinked by either pulling
the trigger, placing the
scanner in the base, or
scanning the Access
Point linking bar code.
(See

Maximum Link

Attempts

on page 3-29.)

The scanner is
relinked by pulling the
trigger, or scanning
the Access Point
linking bar code.

Base or Access
point reset
(firmware upgrade
or power cycle)

Scanner behaves as if
out of range.

No attempt to relink
made while base or
Access Point is
powered off. Trigger
must be pulled to
initiate relinking.

* Auto Reconnect On

Auto Reconnect Off

Advertising