Heath Zenith SL-5326 User Manual

Motion sensor light control with 2-level lighting, Operation, Rite

Advertising
background image

Model SL-5326

D

ual

B

rite

®

Motion

Sensor Light Control
with 2-Level Lighting

© 2006 DESA Specialty Products

598-1269-00

TEST

2 Shells*

Features

• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Softstart lighting technology slowly increases light

intensity when lights turn on and slowly decreases
light intensity when lights turn off.

• D

ual

B

rite

®

Timer.

• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).

TEST 1 5 20

ON-TIME

Off 3 6 Dusk to

Dawn

D

ual

B

rite

®

Put ON-TIME switch
on the sensor bottom
to TEST and the D

ual

-

B

rite

®

switch OFF.

D

ual

B

rite

®

TIMER

Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). If motion is sensed,
the light turns on full bright for the ON-TIME (1, 5,
or 20 minutes) then returns to dim mode.

Mode:

On-Time:

Works: Day Night

Test

5 Sec

x

x

Auto

1, 5, 20 min.

x

Manual

Until Dawn*

x

OPERATION

* resets to Auto Mode at dawn.

MANUAL MODE

ON-TIME

TEST

1 5 20

... back on.

AUTO

1 Second OFF

then...

Put the ON-TIME switch in the 1, 5,
or 20 minute position.

Manual mode only works at night
because daylight returns the sensor
to AUTO.

Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.

Manual mode works only with the
ON-TIME switch in the 1, 5, or 20
position.

Move ON-TIME Switch to

1, 5, or 20 minutes

Mode Switching Summary

Flip light switch off

for one second then

back on*

MANUAL MODE

AUTO

TEST

* If you get confused while switching modes, turn the

power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.

Note: When first turned on wait about 1

1

/

2

minutes for

the circuitry to calibrate.

This package includes:

Light Control

Sensor

Cover

Plate

Lamp

Holders

Plastic Hanger

Rubber Plug

Gasket

6 Screws

(3 sizes included)

Mounting Strap

Mounting Bolt

2 Wire

Connectors

Requirements

• The Light Control requires 120-volts AC.
• If you want to use Manual Mode, the control must be

wired through a switch.

Some codes require installation by a
qualified electrician.

• This product is intended for use with the enclosed

gasket and with a junction box marked for use in wet
locations.

Advertising