Example #4: What are the device’s settings for all Codabar selections?
Enter:

cbr?.

Response:

CBRENA1[ACK],
SSX0[ACK],
CK20[ACK],
CCT1[ACK],
MIN2[ACK],
MAX60[ACK],
DFT[ACK].

This response indicates that the device’s Codabar Coding Enable (CBRENA) is
set to 1, or on;
the Start/Stop Character (SSX) is set to 0, or Don’t Transmit;
the Check Character (CK2) is set to 0, or Not Required;
concatenation (CCT) is set to 1, or Enabled;
the Minimum Message Length (MIN) is set to 2 characters;
the Maximum Message Length (MAX) is set to 60 characters;
and the Default setting (DFT) has no value.

Trigger Commands

You can activate and deactivate the image scanner with serial trigger com-
mands. First, the image scanner must be put in Manual/Serial Trigger Mode
either by scanning the Manual/Serial Trigger Mode barcode (

page 3-3

), or by

sending the Manual/Serial Menu Command (

page 10-12

). Once the image

scanner is in serial trigger mode, the trigger is activated and deactivated by
sending the following commands:

Activate:SYN T CR

Deactivate:SYN U CR

The image scanner scans until a barcode has been read, until the deactivate
command is sent, or until the serial time-out has been reached (see

Read

Time-Out (Serial Trigger Mode)

on page 3-4 for a description, and the serial

command on

page 10-12

).

Resetting the Standard Product Default Settings:
Current Application Work Group

If you aren’t sure what programming options are in your image scanner, or
you’ve changed some options and want the standard product default settings
restored, scan the

Standard Product Default Settings: Current Application

Group barcode below.