Base charge mode, Base charge mode -4 – Honeywell 2020 User Manual

Page 22

Advertising
background image

1 - 4

Base Charge Mode

In order for the battery to be charged, there must be enough voltage for the cir-
cuitry to work. There are three conditions during which power can be supplied
to the base:

Condition 1:9VDC power supply connected to the barrel connector
Condition 2:12VDC host power source only
Condition 3:5VDC host power source only

The chart below describes each selection by condition.

Using a slow charge rate draws less current (power) from the input power
source when the battery is mostly discharged.

Scan the appropriate barcode for your application.

Default = Automatic.

Condition 1

Condition 2

Condition 3

Automatic

Fast Charge

Slow Charge

No Charge

Full Charge Rate

Fast Charge

Fast Charge

No Charge

Low Charge Rate

Slow Charge

Slow Charge

No Charge

Battery Charge Off

No Charge

No Charge

No Charge

* Automatic

Low Charge Rate

Full Charge Rate

Battery Charge Off

Advertising