Interfunction Delay

An interfunction delay of up to 495 milliseconds may be placed between the
transmission of each segment of the message string. Scan the Interfunction
Delay
barcode below, then scan the number of milliseconds and the SAVE bar-
code using the

Programming Chart

inside the back cover of this manual.

To remove this delay, scan the Interfunction Delay barcode, then set the num-
ber of steps to 0. Scan the SAVE barcode using the

Programming Chart

inside

the back cover of this manual.

Intermessage Delay

An intermessage delay of up to 495 milliseconds may be placed between each
scan transmission. Scan the Intermessage Delay barcode below, then scan
the number of milliseconds and the SAVE barcode using the

Programming

Chart

inside the back cover of this manual.

To remove this delay, scan the Intermessage Delay barcode, then set the num-
ber of steps to 0. Scan the SAVE barcode using the

Programming Chart

inside

the back cover of this manual.

Interfunction Delays

Prefix

Scanned Data

Suffix

1

2 3 4 5

STX

HT

CR

LF

Interfunction Delay

2nd Scan Transmission

1st Scan Transmission

Intermessage Delay