3b. Defrost: Control Module with Integrated Display

Refrigerator Defrost Fails to Initiate - Possible Cause

1. Defrost Thermistor (Confirm

DTh status. See "II.D. Thermistor
Check.")

a) Defrost initiation temperature 8.6°F (-13°C) not achieved. See "1. Not

Cooling."

b) Out of position or defective.

2. Compressor Relay

a) Defective.

3. Control Module

a) Defective.

Refrigerator Defrost Fails to Terminate - Possible Cause

1. Defrost Thermistor (Confirm

DTh status. See "II.D. Thermistor
Check.")

a) Defrost termination temperature 40°F (4.4°C) not achieved.

b) Defective.

2. Compressor Relay

a) Defective.

3. Control Module

a) Defrost thermistor connection loose.
b) Defective.

Freezer Defrost Fails to Initiate - Possible Cause

1. Defrost Thermistor (Confirm

DTh status. See "II.D. Thermistor
Check.")

a) Defrost initiation temperature 32°F (0°C) not achieved. See "1. Not

Cooling."

b) Out of position or defective.

2. Compressor 4-hr. cumulative run

timer not satisfied.

a) Check compressor operation. See "1. Not Cooling."

3. Control Module

a) Defective.

Freezer Defrost Fails to Terminate - Possible Cause

1. Defrost Thermistor (Confirm

DTh status. See "II.D. Thermistor
Check.")

a) Defrost termination temperature 59°F (15°C) not achieved.
b) Defrost thermistor connection loose.

2. Defrost Heater

a) Defrost thermostat defective.
b) Defective.

3. Compressor Relay

a) Defective.

4. Control Module

a) Defective.