2. Control Module with Integrated Display

Alarm Signals

Alarm Code Problem

Corrective Action/Reset Details

E01

Cabinet Thermistor Malfunction Alarm

Cabinet thermistor has failed.

Beeps for 10 sec., then silent for 50 sec.. To silence
the alarm, press and release the up button.

Appliance cycles 5 min. on, 5 min. off.

E02

Defrost Thermistor Malfunction Alarm

Defrost thermistor has failed.

Beeps for 10 sec., then silent for 50 sec. To silence
the alarm, press and release the up button.

Appliance cycles on and off with cabinet thermistor.

Hi

High Temperature Alarm

Refrigerator: Cabinet temperature has
remained above 57°F (13.9°C) for more
than 2 hr.

Freezer: Cabinet temperature has
remained above 26°F (-3.3°C) for more
than 2 hr.

Beeps for 10 sec., then silent for 50 sec. To silence
the alarm and clear "Hi" from the display, press and
release the up button. The alarm icon stays on.

Automatically resets when temperature returns to
normal.

Lo

Low Temperature Alarm

Refrigerator: Cabinet temperature has
remained below 26°F (-3.3°C) for more
than 2 hr.

Freezer: Cabinet temperature has
remained below -23°F (-30.6°C) for more
than 2 hr.

Beeps for 10 sec., then silent for 50 sec. To silence
the alarm and clear "Lo" from the display, press and
release the up button. The alarm icon stays on.

Automatically resets when temperature returns to
normal.