Junction box installation, Junction box wiring, Intermittent pilot ignition – Hearth and Home Technologies NOVUS GNBC33 User Manual

Page 13: Novus b-vent installation instructions

Advertising
background image

12-02

13

34615 Rev G

NOVUS B-VENT INSTALLATION INSTRUCTIONS

c. Intermittent Pilot Ignition

This appliance is equipped with an intermittent pilot control valve which operates on a 3 volt system. See wiring

diagram, Figure 15.
The appliance is supplied with a battery pack and a 3 volt AC transformer, which requires the installation of the

supplied junction box. It is highly recommended that the junction box be installed at this time to avoid reconstruction.

The battery pack requires two D cell batteries (not included). Batteries cannot be placed in the battery pack while

using the 3 volt AC transformer. Conversely, the transformer must be unplugged if the battery pack is used.

Figure 15 - Intermittent Pilot Ignition Diagram

Figure 16 - Junction Box Detail

d. Junction Box Wiring

We recommend you operate the two outlets on

separate circuits, one side hot full time, one side

switched. This allows independent operation of the

appliance and fan. Independent operation is

obtained by using minimum 14-3 with ground

Romex and separating the two outlets by breking

out the tab as shown in Figure 16.

6. JUNCTION BOX INSTALLATION INSTRUCTIONS

a. Remove the junction box assembly from the valve

compartment.

b. If the box is being wired from the OUTSIDE of the

appliance:
1) Loosen two screws on the Romex connector,

feed the necessary length of wire through the

connector and tighten the screws.

2) Make all necessary wire connections to the

receptacle and assemble the receptacle and

cover to the junction box.

Note:

This appliance must be electrically wired and grounded in

accordance with local codes or, in the absence of local codes, with

National Electric Code ANSI/NFPA 70-latest edition or the Canadian

Electric Code, CSA C221.1.

CAUTION:

Battery polarity must be correct or control

module damage will occur.

3) Attach the junction box assembly to the

outside of the appliance with the two screws

provided.

c. If the box is being wired from the INSIDE of the

appliance:
1) Pull the electrical wires from outside the

appliance through this opening into the valve

compartment.

2) Loosen the two screws on the Romex

connector, feed the necessary length of wire

through the connector and tighten the screws.

3) Make all necessary wire connections to the

receptacle and assemble the receptacle and

cover to the junction box.

4) Attach the junction box assembly to the inside

of the appliance with the two screws provided.

d. If the box is not to be wired at the time of appliance

installation, assemble the receptacle and cover to

the box and install on the inside of the appliance.