A. applicance specifications, Certification, Codes – Hearth and Home Technologies NOVUS GNBC33 User Manual

Page 4: Gas codes, Certifications/specifications, Vertical installation, Novus b-vent installation instructions

Advertising
background image

34615 Rev G

4

12-02

NOVUS B-VENT INSTALLATION INSTRUCTIONS

1. U.S. AND CANADA CERTIFICATION

The Novus B-Vent Gas Appliance has been tested in

accordance with the ANSI standard Z21.88-2000. In

Canada, the current CSA 2.33-2000, IR41, P4, and IR55

and have been LISTED by Underwriters Laboratories

Inc. for installation as described in this manual. All

components are UL, AGA, CGA or CSA safety certified.

2. LOCAL CODES

This installation must conform with local codes. In the

absence of local codes comply with the National Fuel

Gas Code ANSI Z223.1-latest edition in the U.S.A., and

the CAN/CGA B149, Installation Codes in Canada.

For assistance during installation contact your local

dealer or contact Heatilator Technical Services

Department, Hearth & Home Technologies, 1915 W.

Saunders Street, Mt. Pleasant, Iowa 52641, 1-800-843-

2848.

HEATILATOR® and NOVUS® are registered trademarks

of Hearth & Home Technologies

3. GLASS SPECIFICATIONS/CERTIFICATIONS

Heatilator gas appliances manufactured with tempered

glass may be installed in hazardous locations such as

bathtub enclosures as defined by the CPSC. The

tempered glass has been tested and certified to the

requirements of ANSI Z97.1-1984 and CPSC 16 CFR

1202. (Safety Glazing Certification Council SGCC# 1595

and 1597. Architectural Testing, Inc. Reports 02-

31919.01 and 02-31917.01.)

This statement is in compliance with SPCS 16 CFR

Section 1201.5 “Certification and labeling requirements”

which refers to 15 USC 2063 stating “…Such certificate

shall accompany the product or shall otherwise be

furnished to any distributor or retailer to whom the

product is delivered.”

Some local building codes require the use of tempered

glass with permanent marking in such locations. Glass

meeting this requirement is available from the factory.

Please contact your dealer or distributor to order.

Note:

Minimum and maximum clearances must be main-

tained at all times. Illustrations throughout these instruc-

tions reflect typical installations and are for design purposes

only. Actual installation may vary slightly due to individual

design preferences.
The illustrations and diagrams used throughout these in-

stallation instructions are not drawn to scale.

Tools and building supplies normally required for

installation:
Tools:

Building Supplies:

Saw

Wall-finishing materials

Pliers

Framing material

Hammer

Surround

Phillips screwdriver

Caulking material

Tape measure

Plumb line

Level

Electric drill/bits

Square

Gloves

A. APPLICANCE SPECIFICATIONS

TYPICAL VERTICAL INSTALLATION

We strongly recommend that you DO NOT install B-

Vent Gas Appliances in strong negative air locations,

such as a basement or a public facility. Living rooms

with cathedral ceilings could be susceptible to a

negative air situation, but such installations can be

overcome through raising the termination, depend-

ing on specific installations. This appliance uses

room air for normal operation and could have prob-

lems establishing a positive draft in a negative air

location. In lieu, we recommend a Direct Vent Gas

Appliance.

Advertising
This manual is related to the following products: