L4031A,C POOL HEATER AQUASTAT

®

CONTROLLER

60-2107—5

5

GAS BURNER CONTROL

PP

PP

TH1

TH2

POWERPILE®
GENERATOR

REVERSE-ACTING
PRESSURE CONTOLLER

L4031 POOL HEATER
AQUASTAT® CONTROLLER

POOL
CONTROL

HIGH
LIMIT

M4538

Fig. 6. Typical L4031 connection in a

self-generating gas system.

SETTING AND CHECKOUT

Setting

To set the control point of each control, insert a screwdriver in
the slotted head visible through the cover, and turn the dial of
each control to the desired setting (Fig. 7).

Because systems differ, the correct setting for one system
may not apply to another. In all cases, the equipment manu-
facturer recommendations for setting should be followed.

Checkout

WARNING

CAN CAUSE PROPERTY DAMAGE,
SEVERE INJURY OR DEATH.
This product is intended for use only in systems with a
pressure relieve valve.

Always conduct a thorough checkout when the installation is
complete. Make sure the controller was installed and adjusted
properly by putting it into operation and observing at least one
complete cycle. Further adjustment can then be made to
provide for more exact requirements.

M4540

POOL CONTROL
POINT SETTING
SCREW

HIGH LIMIT
CONTROL POINT
SETTING SCREW

Fig. 7. Internal closeup view of L4031A pool heater

Aquastat

®

Controller setting screws.