System Operation

3-65

GNS-X

L

Flight Management System

Rev. 0
Oct/96

Selecting Exit Mode:

10. Line Select Key - DE-

PRESS to position the
cursor over MANUAL or
AUTO. Press the BACK
key to change exit mode
option. Selecting MANU-
AL
will initiate a continu-
ous hold. Selecting
AUTO will exit the hold
the next time the HP fix is
crossed or after the entry
procedure is completed.
(Figure 3-109)

11. ENT Key - DEPRESS. OK? ENT prompt will appear. Verify inputs.

12. ENT Key - DEPRESS to load the Holding Pattern at the selected

waypoint and return to the NAVIGATION, DIRECT TO, or FPL
Page.

REVIEWING, EDITING, OR CANCELING A HOLDING PATTERN

This procedure enables the pilot to review, edit, or cancel a Holding
Pattern at a specific waypoint.

REVIEWING

1.

NAV, FPL, or

d

Key - DEPRESS to display applicable page.

2.

Line Select Key - DEPRESS to position the cursor over desired HP

waypoint.

NOTE: On NAVIGATION Pages, only the TO Waypoint can be select-
ed, and on the Active Flight Plan, the TO Waypoint can only be

reviewed.

3.

HOLD Key - DEPRESS
to display HOLDING
PATTERN
Page. (Figure
3-110)

4.

Holding Pattern - REVIEW.

AT TRM

(USA)

DIRECT ENTRY

INBOUND CRS

013

MAX HOLDING TAS

259

TURN DIR

RIGHT

LEG TIME

1.0

LEG DIS

(3.2)

EXIT MODE

MANUAL

OK? ENTER

HOLDING PATTERN

1/1

>

>

>

>

Figure 3-109

AT TRM

(USA)

DIRECT ENTRY

INBOUND CRS

013

MAX HOLDING TAS

TURN DIR

RIGHT

LEG TIME

1.0

LEG DIS

(3.2)

EXIT MODE

MANUAL

OK? ENTER

CANCEL

HOLDING PATTERN

1/1

>

>

>

>

Figure 3-110

Advertising