Section 5 database update, Data base update procedures, To update – Honeywell GNS-XL User Manual

Page 255: Database update 5-1

Advertising
background image

Database Update

5-1

GNS-X

L

Flight Management System

Rev. 0
Oct/96

SECTION 5

DATABASE UPDATE

DATA BASE UPDATE PROCEDURES

1.

Apply aircraft power.

2.

Open the hinged door located at the top of the CDU.

3.

Insert current Data Base Update card firmly into the slot. The
double row of holes on
the forward edge of the
card must be inserted
first, with the write pro-
tect slot toward the right
edge of the card. Insert
the card at the same
level as the eject button
located at the right edge
of the slot.

4.

ON Key - DEPRESS to
turn on system. Figure
5-1 appears.

TO UPDATE

CAUTION: IF AN INTERRUPTION OF THE UPDATE PROCESS IS
DESIRED, REMOVE THE UPDATE DISK. DO NOT TURN OFF
POWER TO STOP THE UPDATE.

5.

Line Select or 1 Key - DEPRESS to select BEGIN UPDATE, if
required. If update is not
desired, depress the
Line Select or 2 Key to
select restart NAV.

6.

With cursor over option
1, ENT Key - DEPRESS.
The Update - Data Base
Page and, the message
“X” % “COMPLETE”
appear indicating the
update is in progress.
(Figure 5-2)

TYPE:WW CARD:1/1

REVISION: 3-95

EXPIRES: 13 MAR 95

ENTER CHOICE:

1

BEGIN UPDATE

2

RESTART NAV

(REMOVE CARD)

DATA BASE UPDATE

<

<

Figure 5-1

TYPE:WW CARD:1/1

REVISION: 3-95

EXPIRES: 13 MAR 95

2

%

COMPLETE

DATA BASE UPDATE

<

<

Figure 5-2

Advertising