Figure 4-14, Maxpro configuration tab – Honeywell ULTRAKEY LITE HJC5000 User Manual

Page 62

Advertising
background image

62

Installing UltraKey Lite with MAXPRO-Net

3.

Enter the IP address and Port Number of the MAXPRO-Net server under MAXPRO
Device Network Setting
.

4.

Under Serial Port Setting, select a Baud Rate from the drop-down list. Options are
9600 or 19200 bps.

5.

Select a Connect Mode from the drop-down list. Options are 232 or 422.

6.

From the Joystick speed drop-down list, select Normal or High.

7.

Click Apply to save the configuration, Cancel to exit without saving or Default to
restore all factory default values.

Figure 4-14

MAXPRO Configuration Tab

Checking the Network Connection Using the Ping Function

After the IP address is entered and applied, press the Ping button.

A green Ping button indicates the device at this IP address has replied to the ping.

A red Ping button indicates the device at the IP address did not reply. Please check
that the IP address is correct and that there is a valid network path between the two IP
addresses.

Step 3A: Configure the Controller for a Serial Port Connection

1.

From the side menu, click Serial Port Configuration. See

Figure 4-15

.

2.

Under Serial Port1 Settings, select the following from each drop-down list as
required:

Baud Rate: 9600 or 19200 bps

Parity: none, even or odd

Stop Bits: 1 or 2 bits

Data Bits: 7 or 8 bits

Serial Mode: RS232, RS422 or RS485

3.

If required, repeat

step 2

for Serial Port2 Settings.

Advertising