Maintenance, Maintenance schedule – Honeywell HW2000i User Manual

Page 23

Advertising
background image

HW1000i / HW2000i Inverter Generator Owner’s Manual

www.honeywellgenerators.com

17

MAINTENANCE

Maintenance Schedule

Periodic maintenance and adjustment are necessary to keep the generator in good operating condition. Perform service and
inspection at the intervals shown in the Generator Maintenance Schedule (see Table 3).

Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is a poi-
son you cannot see or smell.

NEVER use inside a home
or garage, EVEN IF doors
and windows are open.

Only use OUTSIDE and far
away from windows, doors, and
vents.

• Shut off engine before performing any maintenance. If

engine must be run, be sure area is well ventilated.

NOTICE

Maintenance, replacement, or repair of the emission
control devices and systems may be performed by any
non-road engine repair establishment or individual.

DANGER

Accidental starting of generator can cause severe injury or
death. Before performing maintenance, disconnect spark
plug cap from spark plug.

Improper maintenance, or failure to correct a problem before
operation, can cause a malfunction in which you can be seri-
ously hurt or killed. Always follow inspection and mainte-
nance recommendations and schedules in this owner's
manual.

NOTICE

The maintenance schedule applies to normal operating con-
ditions. If you operate generator under severe conditions,
such as sustained high-load or high-temperature, or use it in
unusually wet or dusty conditions, consult your servicing
dealer for recommendations applicable to your individual
needs and use.

WARNING

WARNING

MAINTENANCE TASK

FREQUENCY

*

Before

each use

First month
or 25 hours

of use

Every 3

months or

50 hours of

use

Every 4

months or

62.5 hours

of use

Every 6

months or

100 hours of

use

Every

year or

200 hours

of use

Fill fuel tank

X

Check engine oil level

X

Check air cleaner

X

Clean air cleaner

X

Change engine oil (HW1000i)

X

Change engine oil (HW2000i)

X

Check/clean spark plug

X

Clean spark arrestor

X

Check/adjust valve clearance

X

**

Clean fuel tank and strainer

X

**

Check fuel line

Every 2 years (replace if necessary)**

TABLE 3. Generator Maintenance Schedule

*

Perform at every indicated month or operating hour interval, whichever comes first.

† Clean more often when using generator in dusty areas.
‡ HW2000i model only.
** It is recommended that this maintenance task be performed by a service dealer.