Honeywell HW2000i User Manual

Page 26

Advertising
background image

Engine Oil

20

www.honeywellgenerators.com

HW1000i / HW2000i Inverter Generator Owner’s Manual

Engine Oil

6.

Place the oil pan, or other container suitable for hold-
ing engine oil, in front of the generator.

7.

Remove the oil fill cap.

8.

Attach the oil drain pipe (do not over tighten) and tilt
the generator allowing the oil to completely drain into

the oil pan.

9.

Return the unit to the upright position.

10.

Remove the oil drain pipe.

11.

Using a clean cloth, wipe around the drain plug area
to remove any dirt and debris.

12.

Fill the oil fill container (included) with the appropriate
amount and type of new (unused) oil. (See Figure 17
for recommended oil type.)

13.

Slowly pour oil into the oil fill hole. DO NOT OVER-
FILL.

14.

Check the oil level is up to the innermost thread of the
crankcase.

FIGURE 23: Oil Drain Pan

FIGURE 24: Oil Fill Cap Removal

FIGURE 25: Drain Oil (HW2000i Model)

Generator is heavy! Obtain assistance to lift the
generator to avoid back or other bodily injury.

HW1000i

HW2000i

Oil Capacity [qt / ml]

0.26 / 250

0.48 / 450

TABLE 5. Engine Oil Capacity

FIGURE 26: Adding Engine Oil

FIGURE 27: Oil Fill Measurement