Stacking remote condenser units, Fig. 14, Fig. 15 – Hoshizaki KMH-2000SWH/3 User Manual

Page 23

Advertising
background image

23

4) Connect the fan motor leads in the junction box of the remote condenser unit to the fan

motor leads in the fan motor junction box of the icemaker. Use wire of an appropriate
gage and outdoor rating.

5) Replace the junction box covers and the louver panel in their correct positions.

Fig. 14

Screws

Louver Panel

Junction Box
Cover

Remote Condenser Unit

Icemaker

Screw

Fan Motor Junction
Box Cover

Fig. 15

Upper Remote
Condenser Unit

Screws

Lower Remote
Condenser Unit

Screws

7. Stacking Remote Condenser Units

1) Install the lower remote condenser unit as described earlier in this section.
2) Place the upper remote condenser unit on top of the lower. See Fig. 15.
3) Secure the upper remote condenser unit to the lower remote condenser unit with the

4 screws provided.

4) Install refrigerant lines and make electrical connection as described earlier in this

section.

Advertising