Icemaker – Hoshizaki KMH-2000SWH/3 User Manual

Page 25

Advertising
background image

25

1. Icemaker
• Icemaker water supply inlet is 1/2" female pipe thread (FPT). A minimum of 1/2" nominal

copper water tubing is recommended for the icemaker water supply line.

• An icemaker water supply line shut-off valve and drain valve should be installed.
• Icemaker drain outlet is 3/4" FPT. A minimum of 3/4" nominal hard pipe is recommended

for the icemaker drain line. Condensation drain outlet is 3/8" OD hard tube. The
condensation drain line can be connected to the icemaker drain line or can be run
separately.

KMH-2000SRH/3

Fig. 16

Remote Condenser

Line Set Connections

Separate piping to approved drain.

Leave a 2-inch (5-cm) vertical air

gap between the end of each pipe

and the drain.

Icemaker Water Supply

Line Shut-Off Valve

Icemaker Water Supply Line

Drain Valve

Icemaker

Icemaker

Water Supply

Inlet

1/2" FPT

Bin Drain Outlet

See Manufacturer's Instructions

2-inch (5-cm) air gap

Floor Drain

Icemaker

Drain Outlet

3/4" FPT

Bin

Vent Tube

Minimum 1/2" Nominal Copper Water Tubing

Minimum 3/4" Nominal Hard Pipe

Condensation

Drain Outlet

3/8" OD Hard Tube

Vent Tube