Configuration – Honeywell 96D User Manual

Page 18

Advertising
background image

Manning AirAlert-96d Gas Monitor

19073 AIRALERT96D 05/2006 Prelim REVC Copyright © 2006 Honeywell Analytics. All Rights Reserved.

18

7

Configuration

continued

Example of saving a controller configuration

AirAlert96d = “Configuration”
Date = “2006-01-09 13:51:57:”

Parameters (Copying Parameters)

The copying of parameters serves to transfer one
sensor’s configuration to another, or one event to a
second event. This function accelerates
programming on the display when two entities have
identical or close properties.

Tx Info to Tx Info

copies a sensor’s parameters, and

Event to Event

copies the parameters of one event to another.

TxINFO to TxINFO
(copies the parameters of a sensor)

Event to Event

Config (Programming Display Parameters and the
Access Code)

The CONFIG MENU is used to program the display
mode, adjust the time and date, select the display
language in the first window, and to edit the
password in the second window.


[CONFIG]
language = 1
scrollmode = 0
relaymode = 0
password = "2967"
cie = 0
priority = 0
autoload = 1
[SLAVE]
address = 1
protocol = 1
baudrate = 38400
databits = 8
stopbits = 2
parity = 0


[ADDRESS_1]
txtype = 1
display = "ECF9 NH3 AD:01"
protocol = 1
baudrate = 9600
databits = 8
stopbits = 2
parity = 0
sensortype = 65
fullscale = 102.000000
unit = 0
alarmAmin = 20.1000003
alarmAmax = 25.0000000
alarmBmin = 45.000000
alarmBmax = 50.000000
alarmCmin = 85.000000
alarmCmax = 90.000000


[ADDRESS_2]
txtype = 17
display = "ECF9 NH3 AD:02"
protocol = 1
baudrate = 9600
databits = 8
stopbits = 2
parity = 0
sensortype = 2
fullscale = 250.000000
unit = 1
alarmAmin = 20.0000000
alarmAmax = 25.0000000
alarmBmin = 180.000000
alarmBmax = 200.000000
alarmCmin = 218.000000
alarmCmax = 225.000000
databits = 7
stopbits = 2
parity = 0


[GROUP_1]
tx_0 = 1
tx_1 = 2
tx_2 = 0
[EVENT_1]
actiontarget = 14
actionrelay = 1
delaybefore = 0
delayafter = 0
cond1source = 1
cond1logic = 1
cond1alarm = 0
[EVENT_2]
actiontarget = 0
actionrelay = 1
delaybefore = 255
delayafter = 255
cond1source = 129
cond1stat = 9
cond1logic = 7
cond1min = 10.0000000
cond1max = 15.0000000
[FIN]

Tx info to Tx info

source tx001

target tx002

COPY

5. Copy 001

-parameters

Tx info to Tx info

Event to Event

Event to Event

source #001

target #002

COPY

6. Config

Manual scroll mode

Set Date and Time

Menu francais

Advertising