Installation, Venting arrangements – Hampton Direct H25-NG1 User Manual

Page 14

Advertising
background image

14

Hampton

®

H25-1 Direct Vent Freestanding Gas Stove

INSTALLATION

Offset to Vertical Terminations

Venting Arrangements - Horizontal Terminations using Dura-Vent venting system

Dura-Vent Snorkel Termination

Riser Vent Termination

VENTING ARRANGEMENTS

Vertical Terminations Systems for

Residential Manufactured and Mobile Homes

The shaded area in the diagram below shows all allowable combinations of straight
vertical and offset to vertical runs with vertical terminations.
Maximum two 45

o

elbows.

If the vent is ENCLOSED in a chase (min. size 9" x 9") maintain a 1-1/4" clearance to
combustibles.

May be installed in Manufactured (Mobile) Homes after fi rst sale.

Horizontal Terminations for

All Venting Systems

The shaded areas in the diagram below show all
allowable combinations of vertical runs with hori-
zontal terminations. Maximum one 90

O

elbow (two

45

o

elbows equal one 90

o

elbow).

Propane and Natural Gas:

Residential, Manufactured and Mobile

Homes Installations

May be installed in Manufactured (Mobile) Homes

after fi rst sale.

The two diagrams show all allowable com-
binations of straight horizontal termination
with one 45

o

elbow off the unit and Dura-

Vent Snorkel or FPI Riser Vent. Restrictor
position "A".