Installation, H1 h v – Hampton Direct H25-NG1 User Manual

Page 15

Advertising
background image

Hampton

®

H25-1 Direct Vent Freestanding Gas Stove

15

INSTALLATION

Horizontal Venting with Two (2) 90

o

Elbows

Option V

H + H1

A)

2' Min. 4' Max.

B)

3' Min. 5' Max.

C)

4' Min. 6' Max.

D)

5' Min. 7' Max.

E)

6' Min. 8' Max.

Horizontal Venting with Two (2) 90

o

Elbows

Option H

V

H + H1

A)

1' Max. 1' Min. 3' Max.

B)

2' Max. 2' Min. 5' Max.

C)

3' Max. 4' Min. 6' Max.

D)

4' Max. 6' Min. 7' Max.

E)

5' Max. 8' Min. 8' Max.

With these options, max.
total pipe length is 30 feet
with min. of 8 feet total
vertical and max. 8 feet
total horizontal.
Please note min. 1 foot
between 90

o

elbows is

required.

With these options, maxi-
mum total pipe length is 30
feet with minimum of 6 feet
total vertical and maximum
8 feet total horizontal.
Please note minimum 1
foot between 90

o

elbows

is required.

One 90

o

elbow = Two 45

o

elbows.

One 90

o

elbow = Two 45

o

elbows.

H

H1

V

H1

H

V

Vent restrictor position A (fully open), refer to the
"Vent Restrictor Position" section.

Vent restrictor position A (fully open), refer to the "Vent
Restrictor Position" section.

Lengths do not include elbow indicated

Lengths do not include elbow indicated