Installation, H1 h v, V1 v h – Hampton Direct H25-NG1 User Manual

Page 16

Advertising
background image

16

Hampton

®

H25-1 Direct Vent Freestanding Gas Stove

H1

H

V

Vertical Venting with Two (2) 90

o

Elbows

Option V

H

V + V1

A)

1' Min. 4' Max. 2' Min.

B)

2' Min. 5' Max. 3' Min.

C)

3' Min. 6' Max. 4' Min.

D)

4' Min. 7' Max. 5' Min.

E)

5' Min. 8' Max. 6' Min.

Vertical Venting with Two (2) 90

o

Elbows

With these options, max. total
pipe length is 30 feet with min.
of 6 feet total vertical and max.
8 feet total horizontal.
Please note min. 1 foot
between 90

o

elbows is re-

quired.

Option H + H1 V

A)

2' Max. 2' Min.

B)

3' Max. 3' Min.

C)

4' Max. 4' Min.

D)

5' Max. 5' Min.

E)

6' Max. 6' Min.

With these options, max. total
pipe length is 30 feet with min.
of 6 feet total vertical and max.
6 feet total horizontal.
Please note min. 1 foot
between 90

o

elbows is

required.

One 90

o

elbow = Two 45

o

elbows.

One 90

o

elbow = Two 45

o

elbows.

V1

V

H

Vent restrictor position A (fully open), refer to the "Vent
Restrictor Position" section.

Vent restrictor position A (fully open), refer to the "Vent
Restrictor Position" section.

Lengths do not include elbow indicated

Lengths do not include elbow indicated

INSTALLATION