Wsp submersible pump installation diagram, Installation diagram – HONDA WSP33AA User Manual

Page 13

Advertising
background image

11

10

1

/

2

" Min.

14" Min.

Bottom of
inlet pipe

Sump pump

Drill 1/8" relief hole 5" above
pump discharge

Discharge piping can be PVC or
ABS plastic with proper adapters, or
can be galv. steel

shut-off
gate valve
(optional)

Turn on level

Grounded type

115 volt receptacle

min. height above

floor – 4 ft.

13

3

/

8

"

Turn-off level

Lifting handle

Mechanical float switch

*All equipment other than pump to be
supplied by others. Pump only supplied
by Honda.

1

1

/

2

" check valve

with rubber sleeve

connectors

Sump basin 18" to 24" dia.
plastic, fiberglass or concrete

11"

WSP Submersible Pump Installation Diagram

0204 HONDA WSP manual.qxd 3/24/2004 2:14 PM Page 13