Purpose:
This Quick Guide provides the basic instructions for wiring, installing, and
programming the Helios thermostat into a Z-Wave® network. For more
detailed instructions refer to the complete Energy Management
Thermostat Installation and Operation Manual. This is located online at
www.cooperwiringdevices.com/AspireRF.
HVAC System / Thermostat Overview
The RFTSTAT01 connects to the HVAC system’s thermostat connections just
like a traditional thermostat.
HVAC System Compatibility
The RFTSTAT01 is compatible with most heating and cooling systems. There
are two types of HVAC systems:

Standard (gas/electric)
Heat Pump systems

The system type is selectable from the Thermostat Installer Screen by using the Function Control Buttons to access Menu > System Settings
> Mechanical Settings submenu. Refer to the complete Installation and Operation Manual for detailed explanation.
Standard HVAC systems: For Gas heating or Electric heating.
Heat Pump HVAC systems: Supports changeover valve operation for either changeover with cooling or changeover with heating.
Multi-Stage HVAC Compatibility:

For Standard HVAC systems the HVAC outputs support 2 stages of heating and 2 stages of cooling.
For Heat Pump HVAC systems, the HVAC outputs support 3 stages of heating (2 compressor/1 Aux Heat) and 2 stages of cooling.

Remote Communications
The RFSTAT01 is embedded with a Z-Wave module for communicating wirelessesly with Z-Wave compatible control systems.
WIRING / INSTALLATION
The RFTSTAT01 requires 24VAC power from the HVAC system it is controlling. Refer to Figure 1 for connection to a Standard HVAC System
and Figure 2 for a Heat Pump HVAC System.

• Connect the 24V/AC Common (typically the Blue wire/terminal) from the HVAC system to the thermostat terminal block 24Com
• Connect the 24V/AC Return (typically the Red wire/terminal) from the HVAC system to the thermostats HVAC System terminal

block 24RH or 24RC terminals

NOTE – the 24RH and 24RC terminals are default tied together in the thermostat. Most HVAC systems have a common heating and
cooling transformer. If you have a system with separate heating and cooling transformers, you will need to split the RH and RC jumper
by cutting the trace on the PCB. Refer to the complete Thermostat Manual for a detailed explanation.
NOTE – Do NOT split the 24RC/24RH terminals for a Heat Pump system.

RFTSTAT-PT (REV. A)

ENGLISH

IIN

N U

U..S

S..A

A..:: Cooper Wiring Devices, 203 Cooper Circle, Peachtree City, GA 30269 • 866-853-4293

Status

Indicator

LEDs

On-Screen

Dynamic

Button

Labels

Setpoint

Up/Down

Buttons

Heating (H)

and

Cooling (C)

Setpoints

Function Control Buttons

BLUE

RED

WHITE

ORANGE

GREEN

YELLOW

BROWN

C 24V/AC COMMON

R 24V/AC RETURN

W 1 HEAT STAGE 1

W 2 HEAT STAGE 2

G FAN

Y1 COMPRESSOR STAGE 1

Y2 COMPRESSOR STAGE 2

THERMOSTAT CONNECTION

24RH

W1 HEAT

W2/O

G FAN

Y1 COMP

Y2 COMP

24COM
24RC

RFTSTAT01

JP1: Internal RC/RH Jumper

See notes

Typical HVAC system

thermostat wiring color codes

Be sure to verify your systems

wiring color codes

Standard HVAC System

FIG. 1: STANDARD GAS/ELECTRIC HVAC SYSTEM WIRING

BLUE

RED

WHITE

ORANGE

GREEN

YELLOW

BROWN

C 24V/AC COMMON

R 24V/AC RETURN

W 1 AUX HEAT

CHANGE OVER VALUE O or B

G FAN

Y1 COMPRESSOR STAGE 1

Y2 COMPRESSOR STAGE 2

THERMOSTAT CONNECTION

24RH

W1 HEAT

W2/O or B

G FAN

Y1 COMP

Y2 COMP

24COM
24RC

RFTSTAT01

JP1: Internal RC/RH Jumper

See notes

Typical HVAC system

thermostat wiring color codes

Be sure to verify your systems

wiring color codes

Heat Pump HVAC System

FIG. 2: HEAT PUMP HVAC SYSTEM WIRING

Figure 1:
Installation Notes – Standard HVAC System Setup

System Type: Set the system type to Gas/Elect in the Mechanical
Settings menu of the Installer Setup. This is the default setting.
Single Stage systems use W1 for heating stage 1 and Y1 for cooling
stage 1.
Two Stage Heating systems use W1 for stage 1 heating and W2 for
stage 2 heating.
Two Stage Cooling systems use Y1 for stage 1 cooling and Y2 for
stage 2 cooling.
HVAC system transformer: If you have an integrated heating and
cooling system with a single transformer, do NOT cut jumper JP1.
This is typical of most central HVAC systems.

Figure 2 :
Installation Notes – Heat Pump HVAC System Setup
System Type:
Set the system type to Heat Pump in the Mechanical
Settings menu of the Installer Setup.
Single Stage Compressor Systems: Use

Y1 for stage 1 heating/

cooling, and

W1 for stage 2 Aux Heating.

Two Stage Compressor Systems: Use

Y1 for stage 1 heating/cooling

and Y2 for stage 2 heating/cooling and W1 for stage 3 Aux
Heating.
Change Over Valve: You must configure the thermostat’s
changeover valve setting to work correctly with your HVAC system.
Check your HVAC system documentation to be sure.

• Changeover settings are made in the Installer Settings > System

Settings > Mechanical Settings menu.

• Changeover with “Cool” is the default setting and typical for

most systems.

• If you get cooling when you expect heating, change the C/O

type to the opposite setting.