background image

120

www.honeywell.com/sensing

ULTRASONIC DISTANCE SENSORS

948 Series
Thru scan, 2 part

The 948 series perform presence measurement by
using an ultrasonic beam. The 948 series is one of
the smallest ultrasonic scan through devices in the
world. It is especially suited for food and beverage
applications, in particular bottle counting. Easy to
install, the 948 series is suitable when space is at a
premium.

1 switching output
NO/NC; NPN/PNP

Max. sensing distance:

300 mm

Beam angle:

Supply voltage:

18 to 30 V

Sealing:

IP67

Housing:

Plastic rectangular

30,0

(1.18)

2000

(78.74)

12,0

(0.47)

20,0

(0.79)

6,5

(0.04)

5,5

(0.22)

17,0

(0.67)

3,2

(0.13)

10,0

(0.39)

2,0

(0.08)

30,0

(1.18)

2000

(78.74)

12,0

(0.47)

20,0

(0.79)

6,5

(0.04)

5,5

(0.22)

17,0

(0.67)

3,2

(0.13)

10,0

(0.39)

2,0

(0.08)

SWITCHING

REFERENCE

PNP/NO

948-HSY-2D-001-300E

NPN/NO

948-HSY-2D-002-300E

PNP/NC

948-HSY-2D-003-300E

NPN/NC

948-HSY-2D-004-300E

944 Series
Teach in,
Analogue and
2 switching outputs

The new 944 series are microprocessor controlled and fully programmable by teach-in, with the simple
pressing of a button. They offer analogue and two switching outputs through a standard M-12, 5-pin
connector. All the models are IP67 with chemical-resistant body and epoxy face. Parameters are stored in
non-volatile memory.

OPTIONS

2 switching outputs PNP NO
Analogue output 0-10 volts

Beam angle:

Repeatability :

0,4 % or ±2 mm

Supply voltage:

19 to 30 V

Sealing:

IP67

Housing:

M30 x 1,5 mm plastic (PBTB)

M30 x 1,5

3,5

11,2

Max. sensing distance:

3500 mm

Min. sensing distance:

350 mm

Switching frequency:

0,8 Hz

REFERENCE
944-T4V-2D-1C1-130E

Max. sensing distance:

2000 mm

Min. sensing distance:

250 mm

Switching frequency:

1 Hz

REFERENCE
944-T4V-2D-1C1-180E

Max. sensing distance:

1500 mm

Min. sensing distance:

150 mm

Switching frequency:

1 Hz

REFERENCE

944-T4V-2D-1C1-200E

Max. sensing distance:

350 mm

Min. sensing distance:

60 mm

Switching frequency:

8 Hz

REFERENCE

944-T4V-2D-1C1-300E

2 switching outputs PNP NO
Analogue output 4-20 mA

Beam angle:

Repeatability :

0,4 % or ±2 mm

Supply voltage:

19 to 30 V

Sealing:

IP67

Housing:

M30 x 1,5 mm plastic (PBTB)

M30 x 1,5

3,5

11,2

Max. sensing distance:

3500 mm

Min. sensing distance:

350 mm

Switching frequency:

0,8 Hz

REFERENCE
944-T4V-2D-1D1-130E

Max. sensing distance:

2000 mm

Min. sensing distance:

250 mm

Switching frequency:

1 Hz

REFERENCE
944-T4V-2D-1D1-180E

Max. sensing distance:

1500 mm

Min. sensing distance:

150 mm

Switching frequency:

1 Hz

REFERENCE
944-T4V-2D-1D1-200E

Max. sensing distance:

350 mm

Min. sensing distance:

60 mm

Switching frequency:

8 Hz

REFERENCE
944-T4V-2D-1D1-300E

Advertising