Proper application of limit switches, Standards and electrical rating, Actuators – Honeywell Switches and Sensors User Manual

Page 8

Advertising
background image

6

www.honeywell.com/sensing

LIMIT SWITCHES

Proper application of limit switches

The following are guidelines for the correct application of Limit Switches.

Never use the Limit Switch as a physical end stop. Mechanical damage or

incorrect operation may occur if this is done. Always ensure that the

mechanical actuator is protected from excessive mechanical shock. Never

release the actuator suddenly - gradual actuation and release will ensure that

stress on the mechanics of the switch is kept to a minimum. This has the

added benefit that the switch life will be improved. The diagrams illustrate how

to actuate your limit switch for optimum performance.

Standards and Electrical rating

IEC/EN 60947-1 explains the general rules relating to Low Voltage switchgear

and controlgear. The purpose of this standard is to harmonize as much as

possible the product performance and test requirements for equipment where

the rated voltage does not exceed 1,000 Vac or 1,500 Vdc.

IEC 60947-5-1 is part 5 of the general rules which relates to Control-circuit

devices and switching elements, where rated voltage does not exceed 1,000

Vac or 600 Vdc. There are special requirements for control switches with

positive opening operation. These switches are marked on the outside with

this symbol:

The Contact Element form defines the configuration and number of contacts

within the switch.

Form Za – both contact elements have the same polarity

Form Zb – the two contact elements are electrically separated.

The Utilization Category defines the type of current carried – ac or dc – and

the typical application where the switch is used.

The contact rating Designation relates to the Utilization Categories and defines

the conventional thermal current Ith (a) rated operational current Ie (A) at

rated operational voltages Ue and the VA rating.

Actuators

A range of actuators is available for limit switches. Illustrations of actuator

types available from this catalogue are shown at the beginning of each

product family. Other actuators may be available - for more information

please contact your local Honeywell office.

For limit switches with pushrod actuators, the actuating force should be applied as
nearly as possible in line with the pushrod axis.

Cam or dog arrangements should be such that the actuator is not suddently released
to snap back freely.

Operating mechanisms for limit switches shoud be so designed that, under any
operating or emergency conditions, the limit switch is not operated beyond its
overtravel limit position. A limit switch should not be used as a mechanical stop.

For limit switches with lever actuators, the actuating force should be applied as
nearly perpendicular to the lever as practical and perpendicular to the shaft axis
about which the lever rotates.

WRONG

WRONG

RIGHT

FIXED STOP

RIGHT

WRONG

WRONG

RIGHT

RIGHT

over-riding

cam

over-riding

cam

WRONG

WRONG

RIGHT

RIGHT

free position

free position

interference

end of
overtravel

operated
position

end of
overtravel

WRONG

RIGHT

over-riding

non-over-riding

Roller lever

Top roller

lever

Adjustable

roller lever

Top pin

plunger

Top pin

plunger,

boot seal

Top roller

plunger

Top roller

plunger,

boot seal

Top roller

plunger,

perpendicular

Top roller

plunger,

perpendicular,

boot seal

Ball bearing

plunger

Side

roller plunger

Side

pin plunger

Roller lever

Yoke lever

Rod lever

Wobble head