Gss series hinge mount safety limit switch, Safety switches – Honeywell Switches and Sensors User Manual

Page 82

Advertising
background image

80

www.honeywell.com/sensing

GSS Series
Hinge Mount Safety
Limit Switch

The Hinge Mount Safety Limit Switch is designed for use on machine access doors as an alternative solution
to key operated interlocks and safety limit switches. When the access door is opened, a follower pin (not
supplied) slides down the slot in the actuator lever, forcing the actuator lever to rotate and positively open the
NC safety circuit to shut off the machine. Closing the access door rotates the actuator lever to the reset
position, closing the NC safety contacts.
The Hinge Mount Safety Limit Switch minimizes alignment problems because it may be offset-mounted from
the hinge point of the door. The tamper-resistant design and the positive opening contacts provide a higher
level of safety than the conventional spring-driven limit switches often used to monitor door position.

Low Energy Switching

In today’s demanding age of low energy controls, electromechanical switches are frequently used to interface
directly with safety relays, PLCs and other low energy devices. To accommodate this requirement GSS offers
a new gold plated contact version of the standard basic switch. This improves reliability of switching at low
currents and voltages by protecting the contact surfaces from contamination during operation or storage
prior to use.
Standard silver contacts have a disadvantage in that the contact surface may tarnish under certain
environmental conditions, e.g. in the presence of moisture.
Low energy basic switches are rated as follows:
Operating Voltage U

e

1 Vdc to 60 Vdc or 1 Vac to 125 Vac

Operating Current I

e

1 mA to 50 mA

Example of catalog listing using a low energy basic switch - GSCB33S2.

Switching options:

GSC/D

GSE

Snap action contacts (1NC/1NO)

Slow action contacts (4NC)

Zb

22

21

14

13

11

12

21

22

31

32 4Y

41

42

Slow action contacts (1NC/1NO) BBM

Slow action contacts (2NC/2NO) BBM

Zb

21

13

22

14

11

12

21

22

33

34

2Y, 2X

43

44

Slow action contacts (2NC)

Slow action contacts (3NC/1NO) BBM

11

21

12

22

2Y

22

21

11

12

32

31

44

43

3Y, 1X

IEC 60947-5-1/EN 60947-5-1

Designation & Utilization

Rated operational current le (A)

VA

Category

at rated operational voltage Ue

rating

120 V

240 V

380 V

480 V

500 V

600 V

Make

Break

AC15

A600

6

3

1,9

1,5

1,4

1,2

7200

720

AC15

A300

6

3

-

-

-

-

7200

720

AC15

B300

3

1.5

-

-

-

-

3600

360

AC14

D300

0,6

0,3

-

-

-

-

432

72

125 V

250 V

DC13

Q300

0,55

0,27

69

69

DC13

R300

0,22

0,1

28

28

Electrical ratings: