Honeywell BEDIX/KING GPS RNAV User Manual

Page 13

Advertising
background image

BENDIX/KING

KLN 90B

Rev 5, April/2003

10521I05.TDC

Page 1-7

Table 3-9 KLN 90B Signal Outputs

Table 3-10 KLN 90B NAV Flag Output

OBI SYNC,
CLOCK, & DA-
TA:

Honeywell Serial Data containing bearing to the active waypoint

RS 232 OUT:

The RS232 output is designed to interface with certain ARNAV ELTs
and certain moving map displays, storm scopes, and Shadin fuel
flow systems (refer to

Appendix A

)

WPT ALERT:
(Waypoint Alert)

OPEN = Inactive
LOW = Active (Output can sink up to 250 mA

MSG:
(Message)

OPEN = Inactive
LOW = Active (Output can sink up to 250 mA)

APPROACH
ACTIVE:

OPEN = Inactive
LOW = Active (Output can sink up to 250 mA

APPROACH
ARM:

OPEN = Inactive
LOW = Active (Output can sink up to 250 mA

CDI Output:

Output is capable of driving up to five 1 KW parallel loads, Output
drive range:

$

300 mV (

$

150 mV full scale)

30 mV per nautical mile (Full scale = 5 nautical mile)
150 mV per nautical mile (Full scale = 1 nautical mile) 500 mV per
nautical mile (Full scale = .3 nautical mile)(Voltage at pin 22 is rela-
tive to voltage at pin 25)
The CDI output can manually be selected to the sensitivity of one of
the three sensitive modes listed below.

Enroute:

5, 1 or .3 nautical mile scale factor selectable

Approach Arm:

1 or .3 nautical mile scale factor selectable

Approach:

.3 nautical mile scale factor only

Flag Pulled out
of view:

350 to 900 mV

Flag in view:

< 50mVOutput capable of driving up to five 1 KW parallel loads

Nav Super Flag
Output:

Valid = >18 V in 28 VDC aircraft installations; >10 V in 14 VDC air-
craft installations Invalid = <3.5 V in all installations while sinking 1
mA max. Output can source up to 250mA

OBS Resolver
Out:

Nominal output frequency = 450 Hz Nominal unloaded peak ampli-
tude = 6 V Output drive capability = 40mA

Advertising