When troubles occur – haier AB422BCBAA User Manual

Page 22

Advertising
background image

When Troubles Occur

Before contacting the commissioned repair center for after-sales service, please check your
air conditioner according to the following items.

Trouble display

The compressor indicator light flashes 1 time
in 0.2S/time frequency

Phenomenon of outdoor unit trouble

The trouble of outdoor ambient temperature sensor
The trouble of outdoor coil temperature sensor

The outdoor discharging air temperature is too high
Over electric current protection
CT wire breaks

The flashing time of indicator light on
outdoor control panel

1 (A, B systems indicate together)

Detection of abnormal phase sequence

Trouble indication on remote control
type indoor unit

The communication trouble between indoor and

outdoor unit
The protection of too high (too low) pressure

Phenomenon of indoor unit trouble

2 (A and B system indicate individually)

3 (A and B system indicate individually)

4 (A and B system indicate individually)
5 (A and B system indicate individually)

Symptom

Cause

Solution

The unit does not
operate.

The fuse is blown out or the breaker
is open.

Change the fuse or close the
breaker.

Once the unit operates, it
stops immediately.

The air inlet or air outlet of indoor
or outdoor unit is blocked.

Remove the obstacles.

A b n o r m a l o f
C O O L I N G o r
HEATING.

The air inlet or air outlet of indoor
or outdoor unit is blocked.

Remove the obstacles.

Improper set temperature

Referring to page 8

The fan speed is set too low

Referring to page 8

Incorrect swing direction

Referring to page 9

The doors or windows are open

Close them

Direct sunshine

Hang the curtain or blinds before
windows

Too much people in room
Too many heat sources in room

*

COOLING

*

*

COOLING

*

The trouble of outdoor discharging air temperature

sensor

The trouble of indoor ambient temperature sensor

The trouble of indoor coil temperature sensor

The trouble of outdoor ambient temperature sensor

The trouble of outdoor coil temperature sensor

The trouble of electric current overload

Over voltage protection

Excessive and lack voltage protection

The communication trouble between panel and indoor

panel
The communication trouble between indoor panel and
outdoor panel

The trouble of water pump

6 (A and B system indicate individually)
7 (A and B system indicate together)
8 (A and B system indicate individually)

9 (A and B system indicate individually)

20

The compressor indicator light flashes 2 time
in 0.2S/time frequency

The compressor indicator light flashes 9 time
in 0.2S/time frequency

The compressor indicator light flashes 8 time
in 0.2S/time frequency

The compressor indicator light flashes 7 time
in 0.2S/time frequency

The compressor indicator light flashes 6 time
in 0.2S/time frequency

The compressor indicator light flashes 5 time
in 0.2S/time frequency

The compressor indicator light flashes 4 time
in 0.2S/time frequency

The compressor indicator light flashes 3 time
in 0.2S/time frequency

The compressor indicator light flashes 10 time
in 0.2S/time frequency

*

COOLING

*