108

SMV 3000 Transmitter User’s Manual

1/99

9.5

Replacing Meter Body Center Section

Procedure

You can replace the center section of the meter body. A replacement
center section is supplied with a new matching PROM.

Use the procedure in Table 29 to install a new center section and its
matching PROM.

Table 29

Replacing Meter Body Center Section

Step

Action

1

Complete first 7 Steps, as applicable, in Table 28 to remove
electronics module, remove existing PROM, and install matching
PROM supplied with new meter body center section.

2

Use 4mm size allen wrench to loosen set screw outside housing.

3

Carefully unscrew meter body including integral flex-tape assembly
counterclockwise from electronics housing.

Slot for Set Screw

Center Section

Process
Heads

Meter Body

Continued on next page