Honeywell SMV 3000 User Manual

Page 27

Advertising
background image

1/99

SMV 3000 Transmitter User’s Manual

15

3.2

Considerations for SMV 3000 Transmitter,

Continued

Temperature limits

Table 2 lists the operating temperature limits for reference.

Table 2

Operating Temperature Limits

Transmitter Type

Ambient

Temperature

Meter Body

Multivariable

°

C

°

F

–40 to 93

–40 to 200

–40 to 125 *
–40 to 257 *

* For CTFE fill fluid, the rating is –15 to 110

°

C (5 to 230

°

F)

Overpressure ratings

Table 3 lists overpressure rating for a given Upper Range Limit (URL) for
reference.

Table 3

Transmitter Overpressure Ratings

SMV 3000

Transmitter Model

Upper Range Limit (URL)

Overpressure Rating

SMA110

25 inches H2O @ 39.2

°

F (differential pressure)

100 psi

100 psia (absolute pressure) *

100 psi

SMA125

400 inches H2O @ 39.2

°

F (differential pressure)

3000 psi

750 psia (absolute pressure) *

3000 psi

SMG170

400 inches H2O @ 39.2

°

F (differential pressure)

3000 psi

3000 psig (gauge pressure)

3000 psi

* Static pressure is referenced at high pressure port.