HE360A,B POWERED FLOW-THROUGH HUMIDIFIER

68-0194—2

4

M12813

CLIP

CLIP

Fig. 5. Position securing clips.

7. Position the humidifier housing in the hole (be sure it

is level), so the locking tabs are in place on the
upper and lower sheet metal edges of the hole.

8. Push in the securing clips until completely seated.
9. Drill holes and install the three sheet metal screws at

the top of the humidifier housing. Secure the housing
with the three remaining screws at the bottom of the
housing.

10. Reinstall the humidifier pad assembly in the

humidifier housing.

IMPORTANT

For proper operation, be sure the mark on the
end of the humidifier pad is facing up. Check that
the water feed tube is placed in the guide slots of
the humidifier housing.

11. Hook the top of the cover to the housing and secure

with the thumbscrew located at the bottom of the
cover.

:,5,1*+80,',),(5

WARNING

Serious Personal Injury or Equipment Hazard.
Moving parts can cause electrical shock and
injury.

Disconnect power supply before installation or
servicing.

This device contains a moving fan blade; do not
operate the humidifier without the cover
securely attached.

All wiring must comply with applicable local codes,
ordinances and regulations.

)RU++XPLGLVWDW+&RQYHUWLEOH+XPLGLW\

&RQWURO:LULQJ&RQQHFWLRQV

IMPORTANT

Select models of fan centers include humidifer
taps so the current sensing relay or sail switch is
not needed.

If not using a current sensing relay or sail switch,
the 120V humidifier plug must be energized
during blower motor cycles for proper operation.

1. Wire the current sensing relay or sail switch.
2. Connect only the two yellow wires to the humidity

control (red wire connections are not used for
mechanical humidity control). See the typical wiring
diagrams in Fig. 6 through 8.

For additional mounting and wiring information, refer to the
humidity control installation instructions.

)RU+$XWRPDWLF+XPLGLW\&RQWURO:LULQJ

&RQQHFWLRQV

IMPORTANT

Current sensing relay or sail switch is not needed
with the Automatic Humidity Control.

1. Connect the two red and two yellow wires to the

electronic humidity control as shown in Fig. 9.

For additional mounting and wiring information, refer to the
humidity control installation instructions.

HUMIDIFIER

MECHANICAL
HUMIDISTAT

120 VAC

TO BLOWER
MOTOR
IGNITION BOX

M12686

YELLOW WIRES

1

1

2

2

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.

24V WIRING.

Fig. 6. Typical wiring diagram for humidifier using fan

control to cycle blower motor fan and humidifier

simultaneously.

CURRENT
SENSING
RELAY

HUMIDIFIER

120 VAC

BLOWER
MOTOR

C

LO

HI

M12684

YELLOW WIRES

1

1

2

2

POWER SUPPLY.
PROVIDE DISCONNECT
MEANS AND OVERLOAD
PROTECTION AS REQUIRED.

24V WIRING.

MECHANICAL
HUMIDISTAT

Fig. 7. Typical wiring diagram of current sensing relay

with humidifier.