Honeywell Chronotherm IV T8611G User Manual

T8611g chronotherm, Iv deluxe programmable heat pump thermostats, Caution

Advertising
background image

Wallplate Installation

The thermostat can be mounted horizontally on the wall
or on a 2 in. x 4 in. wiring box. Position wallplate
horizontally on the wall or on a 2 in. x 4 in. wiring box.

1. Position and level the wallplate (for appearance

only). The thermostat will function properly even
when not level.

2. Use a pencil to mark the mounting holes. See

Fig. 2.

3. Remove the wallplate from the wall and drill two

3/16 inch holes in the wall (if drywall) as marked.
For firmer material such as plaster, drill two 7/32
inch holes. Gently tap anchors (provided) into the
drilled holes until flush with the wall.

4. Position the wallplate over the holes, pulling wires

through the wiring opening.

5. Loosely insert the mounting screws into the holes.
6. Tighten mounting screws.

WIRING

All wiring must comply with local electrical codes and
ordinances. Refer to Fig. 3 for typical hookup. A letter
code is located near each terminal for identification.

CAUTION

Disconnect power before wiring to prevent
electrical shock or equipment damage.

1. Loosen the terminal screws on the wallplate and

connect the system wires. See Fig. 4.

X-XX UL

INSTALLATION INSTRUCTIONS

®U.S. Registered Trademark
Copyright © 1997 Honeywell Inc. • • All Rights Reserved

T8611G Chronotherm

®

IV

Deluxe Programmable

Heat Pump Thermostats

APPLICATION

The T8611G Chronotherm® IV Deluxe Programmable Heat Pump Thermostats provide electronic control of 24 Vac
single-zone heat pump systems. Refer to Table 1 for a general description of the thermostats. All T8611 thermostats
require a common wire to supply power.

Table 1. Description of T8611 Thermostats.

RECYCLING NOTICE

If this control is replacing a control that contains
mercury in a sealed tube, do

not place your old

control in the trash.

Contact your local waste management authority
for instructions regarding recycling and the proper
disposal of the old thermostat.

INSTALLATION

When Installing this Product…

1. Read these instructions carefully. Failure to follow

the instructions can damage the product or cause
a hazardous condition.

2. Check the ratings given in the instructions and on

the product to make sure the product is suitable for
your application.

3. Installer must be a trained, experienced service

technician.

4. After completing installation, use these instructions

to check out the product operation.

Location

Install the thermostat about 5 ft (1.5m) above the floor in
an area with good air circulation at average temperature.
See Fig. 1.

Do not install the thermostat where it can be affected by:

drafts, or dead spots behind doors and in corners.

hot or cold air from ducts.

radiant heat from sun or appliances.

concealed pipes and chimneys.

unheated (uncooled) areas such as an outside wall
behind the thermostat.

T8611

Changeover

System Selection

Fan Selection

Comments

G

Automatic

Em Heat-Heat-Off-Cool-

Auto

On-Auto

System and fan selections are done by keyboard.

69-0936-1

Advertising