W8835 ENVIRAZONE PANEL

68-0258—04

4

Table 2. Required Accessories (Not Supplied with Panel).

a

Supplied in the Y8835 kits.

INSTALLATION

Mounting

CAUTION

Equipment Damage Hazard.

Do not mount W8835 inside HVAC equipment.

Mount only on wall or on cold air return.

1. Mount the thermostats in each zone of the living space

using the installation instructions provided with each

thermostat.

2. Mount the dampers in the ductwork using the installation

instructions provided with each damper.

3. Mount the W8835 EnviraZone Panel near the HVAC

equipment; locate it on a wall or on the cold-air return.

See Fig. 2.

4. Level the W8835 for appearance only.

Fig. 2. W8835 mounting location.

Wiring

CAUTION

Voltage Hazard.

Can cause electrical shock or equipment damage.

Disconnect power before continuing installation.

Wiring must comply with applicable codes, ordinances,

and regulations.

Accessory

Description

Bypass Rating

(cfm)

40 VA transformers

AT140A1042

a

High and low limit sensor

C7835A1009

a

Round static pressure regulator damper

SPRD7

SPRD8

SPRD9

SPRD10

SPRD12

SPRD14

SPRD16

300

400

600

750

1200

1800

2400

Rectangular static pressure regulator damper

SPRD12x8

SPRD12x10

SPRD12x12

SPRD20x8

SPRD20x10

SPRD20x12

1000

1200

1400

1600

2000

3000

M31121

W8835

ELE

CTRONI

C AIR

CLEANER

RETURN

AIR

W8835

FURNACE

AIR CLEANER