34-ST-03-57

Page 15


Options

Ordering Information

Mounting Bracket

The angle-mounting bracket is
available in either zinc-plated
carbon steel or stainless steel and
is suitable for horizontal or vertical
mounting on a two-inch (50
millimeter) pipe, as well as wall
mounting. An optional flat
mounting bracket is also available
in carbon steel for two inch (50
millimeter) pipe mounting.
Indicating Meter
(Options ME and SM)
Two integral meter options are
available. An analog meter (option
ME) is available with a 0 to 100%
linear scale. The Smart Meter
(option SM) provides an LCD
display for both analog and digital
output and can be configured to
display pressure in pre-selected
engineering units.
Lightning Protection
(Option LP)
A terminal block with circuitry that
protects the transmitter from
transient surges induced by
nearby lightning strikes is
available.

HART

®

Protocol Compatibility

(Options HC and H6)
Optional electronics modules for
the ST 3000 provides HART
Protocol compatibility in either
HART 5.x or 6.x formats.
Transmitters with a HART Option
are compatible with any HART
enabled system that provides 5.x
or 6.x format support.
F

OUNDATION

Fieldbus

(Option FF)

Equips transmitter with FF
protocol for use in 31.25 kbit/s FF
networks. See document 34-ST-
03-72 for additional information on
ST 3000 Fieldbus transmitters.
SIL2/SIL3 Certification
(Option SL)
This ST 3000 product is available
for use with safety systems. With
the SL option, we are fully certified
to SIL 2 capability for single
transmitters and SIL 3 capability for
multiple transmitter use through
TÜV Nord Sys Tec GmbH & Co.
KG.

(continued)

We are in compliance with the
following SIL standards:

IEC 61508-1: 1998;

IEC 61508-2: 2000;

IEC 61508-3: 1998

NAMUR NE43 Compliance
(Option NE)
This option provides software the
meets the NAMUR NE43
requirements for failsafe software.
Transmitter failure information is
generated when the measuring
information is no longer valid.
Transmitter failure values are:
≤ 3.6 mA and ≥ 21.0 mA. The
normal ST 3000 ranges are ≤ 3.8
mA and ≥ 20.5 mA.
Indicator Configuration
(Option CI)
Provides custom configuration of
Smart Meters.
Tagging (Option TG)

Up to 30 characters can be added
on the stainless steel nameplate
mounted on the transmitter’s
electronics housing at no extra
cost. Note that a separate
nameplate on the meter body
contains the serial number and
body-related data. A stainless
steel wired on tag with additional
data of up to 4 lines of 28
characters is also available. The
number of characters for tagging
includes spaces.
Transmitter Configuration
(Option TC)

The factory can configure the
transmitter linear/square root
extraction, damping time, LRV,
URV and mode (analog/digital)
and enter an ID tag of up to eight
characters and scratchpad
information as specified.
Custom Calibration and ID in
Memory (Option CC)

The factory can calibrate any
range within the scope of the
transmitter’s range and enter an
ID tag of up to eight characters in
the transmitter’s memory.

Contact your nearest Honeywell sales
office, or

In the U.S.:

Honeywell

Industrial Automation & Control

16404 North Black Canyon Hwy.

Phoenix, AZ 85053

1-800-288-7491

In Canada:

The Honeywell Centre

155 Gordon Baker Rd.

North York, Ontario M2H 3N7

1-800-461-0013

In Latin America:

Honeywell Inc.

480 Sawgrass Corporate Parkway,

Suite 200

Sunrise, FL 33325

(954) 845-2600

In Europe and Africa:

Honeywell S. A.

Avenue du Bourget 1

1140 Brussels, Belgium


In Eastern Europe:

Honeywell Praha,

s.r.o. Budejovicka 1

140 21 Prague 4,

Czech Republic

In the Middle East:

Honeywell Middle East Ltd.

Khalifa Street,

Sheikh Faisal Building

Abu Dhabi, U. A. E.

In Asia:

Honeywell Asia Pacific Inc.

Honeywell Building,

17 Changi Business Park Central 1

Singapore 486073

Republic of Singapore

In the Pacific:

Honeywell Pty Ltd.

5 Thomas Holt Drive

North Ryde NSW Australia 2113

(61 2) 9353 7000

In Japan:

Honeywell K.K.

14-6 Shibaura 1-chrome

Minato-ku, Tokyo, Japan 105-0023

Or, visit Honeywell on the World Wide
Web at:

http://www.honeywell.com


Specifications are subject to change without
notice. (Note that specifications may differ
slightly for transmitters manufactured before
October 30, 1995.)

Advertising
This manual is related to the following products: