Physical and approval bodies – Honeywell ST 3000 SMART TRANSMITTER STR93D User Manual

Page 9

Advertising
background image

34-ST-03-57

Page 9


Physical and Approval Bodies

Parameter

Description

Process Interface

See Model Selection Guide for Material Options for desired Seal Type.

Seal Barrier Diaphragm

316L Stainless Steel, Monel, Hastelloy C, Tantalum

Seal Gasket Materials

Klinger C-4401 (non-asbestos)
Grafoil Teflon Gylon

3510

Mounting Bracket

Carbon Steel (zinc-plated) or Stainless Steel angle bracket or Carbon Steel flat
bracket available.

Fill Fluid (Meter Body)

Silicone (DC 200)

S.G. @ 25°C (77°F) = 0.94

CTFE (Chlorotrifluoroethylene)

S.G. @ 25°C (77°F) = 1.89

Fill Fluid (Secondary)*

Silicone (DC 200)

S.G. @ 25°C (77°F) = 0.94

CTFE (Chlorotrifluoroethylene)

S.G. @ 25°C (77°F) = 1.89

Silicone (DC 704)

S.G. @ 25°C (77°F) = 1.07

Syltherm 800

S.G. @ 25°C (77°F) = 0.90

NEOBEE M-20

S.G. @ 25°C (77°F) = 0.93

Electronics Housing

Epoxy-Polyester hybrid paint. Low-copper aluminum alloy. Meets NEMA 4X
(watertight) and NEMA 7 (explosion proof)

Capillary Tubing

**

Armored Stainless Steel or PVC Coated Armored Stainless Steel. Length: 5, 10,
15, 20, 25 and 35 feet (1.5, 3, 4.6, 6.1, 7.5 and 10.7m). A 2” (51 millimeter) S.S.
close-coupled nipple is also available. See Model Selection Guide.

Wiring

Accepts up to 16 AWG (1.5 mm diameter)

Mounting

See Figure 16.

Dimensions

See Figures 19 and 20 for transmitter dimensions. See Model Selection Guide for
Seal dimensions

Net Weight

Transmitter: 4.1 Kg (9 lbs). Total weight is dependent on seal type and capillary
length.

Approval Bodies



Factory Mutual

Explosion Proof:

Approved as Explosion Proof for Class I, Division 1, Groups A,

B, C, D locations,

Dust Ignition Proof:

Approved as Dust Ignition Proof for Class II, III, Division 1,

Groups E, F, G locations,

Intrincically Safe:

Approved as Intrinsically Safe for for Class I, II, III, Division 1,

Groups A, B, C, D, E, F, G locations.

Nonincendive:

Approved as Nonincendive for Class I, Division 2, Groups A, B, C,

D locations.


CSA

Explosion Proof:

Approved as Explosion Proof for Class I, Division 1, Groups B,

C, D locations,

Dust Ignition Proof:

Approved as Dust Ignition Proof for Class II, III, Division 1,

Groups E, F, G locations,

Intrincically Safe:

Approved as Intrinsically Safe for Class I, II, III, Division 1,

Groups A, B, C, D, E, F, G locations.

Canadian Registration

Number (CRN)

All ST 3000 model designs, except SATG19L, STG99L, STG170 and STG180

have been registered in all provinces and territories in Canada and are marked

CRN:0F8914.5c.

ATEX

Intrinsically Safe, Zone 0/1: EEx ia IIC T4, T5, T6
Flameproof/Zone 1:

EEx d IIC T5, T6 (enclosure IP 66/67)

Non-Sparking, Zone 2:

EEx nA, IIC T6 (enclosure IP 66/67)

Multiple Markings:

Ex II 1 G: EEx ia IIC T4, T5, T6, Ex II 2 G: EExd IIC T5, T6

Ex II 3 G: EEx nA, IIC T6 (Honeywell) (enclosure IP 66/67)

SA (Australian)

Intrinsically Safe:

EX ia IIC T4

Non-Sparking:

Ex n IIC T6 (T4 with SM option)

INMETRO (Brazil)

Flame-Proof, Zone 1:

EX d IIC T5

Advertising