Honeywell Stryker VAV 62-2030-01 User Manual

Page 3

Advertising
background image

STRYKER VAV USER GUIDE

3

62-2030—01

1.4 Icons available in the Stryker VAV Configuration Tool

Table 2. Available Icons.

Tip

• Numeric values are stored in the application in a defined

unit. When these values are loaded in the configuration

wizard they may be displayed in a different unit. Each unit

has a defined precision. Because of this difference in the

precision and the unit, there may be loss of data when

loading the numeric values into the wizard and when

saving the numeric values. This loss of data is of very small

magnitude and will not affect the functioning of the

controller.

You may experience this loss during the following

scenarios.

— Setting the unit system to English and entering values

in fields such as flow set points and temperature set

points.

— Entering numeric values that are very close to the

valid range for a given field.

• When the configuration is uploaded from the device, if the

input and output configuration in the device is different from

the input and output configuration in the database then the

user configured input and output names will be lost. The

default input and output names will be displayed.

• The progress bar indicates the current progress in the

wizard. Sometimes it may take few minutes to load the

progress bar, and the progress bar will not give the

accurate progress during loading.

• Each unit has a pre-defined configuration. If the user

configures the device different from the pre-defined

configuration, the wizard displays a warning message. The

warning message is just to notify the user about the

configuration. The user can ignore the warning message

and continue with the configuration.

For Example:

Predefined configuration: A Series Fan configuration should be combined with the Pressure Independent air flow con-

trol.

Actual Configuration: If the user combines the Series Fan configuration with the Pressure Dependent air flow control,

the wizard displays the following warning message.

• To view all the warning messages displayed during the configuration, click the

button. The warning

messages are displayed as shown in the following image.

RELATED TOPICS

“2. Configuration” on page 4

Device Icon

Icon Status

Description

Download State

This icon indicates that the configuration from the station has been

written to the device via the Asc Download action or the configuration

from the device has been updated in the station via the Asc Upload

action.

Download Pending State

This is a download pending icon. It appears when the device is

dropped onto the Nav pane.