How Does The Hubbell Tankless Water Heater Work?

Hubbell has applied its 90 years of water heating experience and engineered a tankless electric water heater

that will provide many years of reliable service in your home. The cold water enters the unit and passes

through a flow meter and inlet thermistor which measure the precise flow rate and temperature of the

incoming water. The control system uses advanced logic with solid state switching devices to fully

modulate the power to the heating elements from 0-100% to provide the most accurate and consistent hot

water temperatures in the industry. As the water flows out of the unit a second thermistor makes any

necessary adjustments to ensure the Hubbell Tankless delivers accurate and consistent hot water. With

numerous control features including the ability to track kW hours consumed, operating cost and hot water

usage, the Hubbell Tankless allows the homeowner to maximize their savings and gain the most benefit from

their investment.

Electrical Requirements

Hubbell Tankless Model No.

110-2 145-2 165-2 180-2

280-3

If actual supply voltage is less than 240V, the kW

will be reduced, see de-rating factors below:

If 230 Volt multiply kW by 0.92

If 220 Volt multiply kW by 0.84

If 208 Volt multiply kW by 0.75

To solve for flow rate using a derated kW use the formula:

kW x 6.824 ÷ °FΔT = GPM

°

FΔT = Change in Temperature (Hot - Cold)

Electrical Requirements

kW @ 240V

11

14

16

18

21

24

27

Amps @ 240V

45.8

58.3

66.7

75.0

87.5

100.0

112.5

Min. Recommended Amperage to Home

100

100

125

150

200

200

200

Multiple Circuit Breaker Installation (US Only)

Minimum Double-Pole Circuit
Breaker Size

(quantity x amps)

2 x 25

2 x 35

2 x 40

2 x 40

2 x 50

2 x 60

2 x 60

3 x 40

3 x 40

Min. Feed Wire Size at 75°C

THHN or Equivalent (AWG Copper)

8

8

8

8

8

6

6

8

8

Single Circuit Breaker Installation (Canada & US)

Minimum Double-Pole Circuit

Breaker Size

(quantity x amps)

1 x 50

1 x 70

1 x 80

1 x 80 1 x 100 1 x 110 1 x 125

Min. Feed Wire Size at 75°C

THHN or Equivalent (AWG Copper)

8

6

4

4

3

2

1

PROUDLY MADE IN THE USA