C] sanitizing solution, D] sanitizing procedure, C] sanitizing solution [d] sanitizing procedure – Hoshizaki SELF-CONTAINED CRESCENT CUBER KM-250BAF User Manual

Page 18

Advertising
background image

18

[c] Sanitizing Solution

Dilute 1 fl. oz. (30 ml or 2 tbs) of 5.25% sodium hypochlorite solution (chlorine bleach)
with 2 gallons (7.6 l) of warm water. Using a chlorine test strip or other method, confirm
that you have a concentration of about 200 ppm.

IMPORTANT

For safety and maximum effectiveness, use the solution immediately after
dilution.

[d] Sanitizing Procedure

The sanitizing process will sanitize the icemaker.

1) Wash the bin liner, thermostat bracket, water tank, overflow pipe, O-ring, and overflow

cap using the sanitizing solution. If possible, soak the water tank, overflow pipe and
overflow cap in the sanitizing solution in a clean container for 10 minutes.

2) Discard the sanitizing solution and rinse the parts in the previous step thoroughly with

water.

3) Replace the parts in their correct positions.

Note: Be sure to correctly replace the overflow-pipe O-ring to prevent leaks.

4) Pull out the cap at the front of the plastic body 1" or more.

5) Mix a new batch of the sanitizing solution and pour it into the water tank.

6) Replace the cap in its correct position.

7) Allow the sanitizer to sit for 10 minutes.

8) Move the control switch to the “WASH” position.

9) Close the door.

10) After 15 minutes, move the control switch to the “OFF” position.

11) Open the door.

12) Remove the plug to drain the water tank. After draining, replace the plug in its correct

position.

13) Repeat 5) through 12) one time then go to 14).

Advertising