CONTROL PANEL OPERATION

9

Dehumidifying and cooling operation

The operating range for cooling operation is 60°F - 90°F,

and the operating range for dehumidifying is 68°F - 88°F.
Power source
• The AC socket must be firm and reliable.

• Don’t connect the portable air conditioner to a multiple

socket outlet which is also being used for other electrical

appliances.

• Insert the AC power plug securely into the AC socket before

using the unit, when it beeps after two seconds, press ON/

OFF button, the unit begins to run.

LCDI power cord information

All Friedrich portable air conditioners are shipped from the

factory with a Leakage Current Detection Interrupter (LCDI)

equipped power cord. The LCDI device meets the UL and

NEC requirements for cord connected air conditioners effec-

tive August 2004.
To test your power supply cord:
1. Plug power supply cord into a grounded 3 prong outlet.
2. Press RESET (See drawing below).
3. Press TEST (listen for click; Reset button trips and pops

out).

4. Press and release RESET (listen for click; Reset button

latches and remains on). The power supply cord is ready

for operation.

NOTE: LCDI device is not intended to be used as a switch.

Once plugged in the unit will operate normally without the

need to reset the LCDI device.
If the device fails to trip when tested or if the power supply

cord is damaged it must be replaced with a new supply cord

from the manufacturer. We recommend you contact our

Technical Assistance Line at (800) 541-6645. To expedite

service, please have your model and serial number available.

WARNING: NEVER

CUT OR REMOVE

THE GROUNDING

PRONG FROM

PLUG. NEVER USE

EXTENSION CORDS

TO OPERATE AN

AIR CONDITIONER.

TEST

RESET

Test Button

Reset Button

Test Button

Reset Button

Mode control

The mode control has three settings– Cool, Dehumidify

and Fan. The settings are adjusted with the Mode Control

button. A light will indicate which setting is currently being

used.

Cooling operation

1. Press MODE button to choose the cooling mode, LCD

window will show “cool”.
During the cooling operation, always place the air exhaust

hose through an open window.

2. Repeatedly press TEMP + or TEMP - button to set a

proper room TEMP. between 60°F - 90°F.

3. Press FAN SPEED button to choose between low,

medium and high speeds.

NOTE:

In order to improve the cooling efficiency:

a) If your room is directly exposed to the sun, draw the

curtains.

b) Do not place near other heat source.

1. Keep the windows and the doors closed to aid in effectively

dehumidifying the room.
2. Press MODE button to choose the dehumidifying mode,

LCD window will show “DRY”, the fan speed cannot be

adjusted.

When used as dehumidifier only it is not necessary to install

the exhaust hose.

To set the time to start the machine, with the unit off (but power

supplied), press TIMER button, the LCD window will show

”, continually press the TIMER button, set the preferred

start time. The setting range is 1-24 hours.
To set the time to stop the machine, with the unit running,

press TIMER button, the LCD window will show “

”,

continually press the TIMER button ,set the preferred time to

stop the machine. The setting range is 1-24 hours
NOTE: During timer mode if the TIMER button is pressed

again it will cancel the timer operation.

Warning Light

Condensed water may accumulate in the unit. If the internal

tank becomes full, the Warning Light will come on and the

unit will not operate until the unit has been drained.

Dehumidifying Operation

Time Set Function