Interface

5-4

C141-E224

5.1.2 Signal interface regulation

5.1.2.1 Out of band signaling

During OOB signaling transmissions, the differential and common mode levels of
the signal lines shall comply with the same electrical specifications as for in-band
data transmission, specified as follows.

COMRESET/COMINIT

106.7 ns

320 ns

COMWAKE

106.7 ns

106.7 ns