Specifications, General specifications, Environmental – Fluke 52 User Manual

Page 12: Electrical

Advertising
background image

51, 52, 53, 54 Series II

Service Manual

4

Specifications

General Specifications

Weight

280 g (10 oz)

Dimensions
(without holster)

2.8 cm

×

7.8 cm

×

16.2 cm

(1.1 in

×

3 in

×

6.4 in)

Battery

3 AA batteries

Certification

P

,

)

(TÜV pending)

Safety

CSA C22.2 No. 1010.1 1992
EN 61010 Amendments 1, 2

CAT I

OVERVOLTAGE (Installation) CATEGORY I,
Pollution Degree 2 per IEC1010-1*

* Refers to the level of Impulse Withstand Voltage protection provided. Equipment of OVERVOLTAGE
CATEGORY I is equipment for connection to circuits in which measures are taken to limit the transient
over voltages to an appropriate low level.

Environmental

Operating Temperature

10

o

C to

+

50

o

C (+14

o

F to

+

122

o

F)

Storage Temperature

40

o

C to

+

60

o

C (

40

o

F to

+

140

o

F)

Humidity

Non Condensing (< +10

o

C) (< +50

o

F)

95% RH (+10

o

C to +30

o

C) (+50

o

F to +86

o

F)

75% RH (+30

o

C to +40

o

C) (+86

o

F to +104

o

F)

45% RH (+40

o

C to +50

o

C) (+104

o

F to +122

o

F)

(Without Condensation)

Electrical

Measurement
Range

J-type:

210

o

C to

+

1200

o

C (

346

o

F to

+

2192

o

F)

K-type:

200

o

C to

+

1372

o

C (

328

o

F to

+

2501

o

F)

T-type:

250

o

C to

+

400

o

C (

418

o

F to

+

752

o

F)

E-type:

150

o

C to

+

1000

o

C (

238

o

F to

+

1832

o

F)

N-type:

200

o

C to

+

1300

o

C (

328

o

F to

+

2372

o

F)

R- and S-type: 0

o

C to

+

1767

o

C (

+

32

o

F to

+

3212

o

F)

Display
Resolution

0.1

o

C /

o

F / K

<

1000

o

1.0

o

C /

o

F / K

1000

o

Measurement
Accuracy

J-, K-, T-, E-, and N-type:

±

[0.05

%

of reading

+

0.3

o

C (0.5

o

F)]

[below

100

o

C (

148

o

F): add 0.15 % of reading for J, K, E, and N;

and 0.45 % of reading for T]
R- and S-type:

±

[0.05

%

of reading

+

0.4

o

C (+0.7

o

F)]

Temperature
Coefficient

0.01

%

of reading

+

0.03

o

C per

o

C

(0.05

o

F per

o

F) outside the specified

+

18

o

C to +28

o

C (

+

64

o

F to

+

82

o

F) range

[below

100

o

C (

148

o

F): add 0.04 % of reading for J-, K-, E-, and N-type;

and 0.08 % of reading for T-type]

Electromagnetic
Compatibility

Susceptibility:

±

2

o

C (

±

3.6

o

F) for 80 MHz to 200 MHz in 1.5 v/m field, for 200 MHz to

1000 MHz in 3 V/m field.
Emissions: Commercial limits per EN50081-1

Maximum
Differential
Common Mode
Voltage

1 V (Maximum voltage difference between T1 and T2)

Temperature
Scale

ITS-90

Applicable
Standards

NIST-175

Accuracy is specified for ambient temperatures between +18

o

C (+64

o

F) and +28

o

C (+82

o

F) for a period of

1 year. The above specifications do not include thermocouple error.

Advertising
This manual is related to the following products:

53, 51, 54