configure router rip timers flush

This command configures the global RIP flush timer.

This is the time interval in seconds that must pass before the route is removed from the routing table. This value
should be configured to be greater than the configured holddown time value.

Parameter

Description

syntax:

[ no ] flush time < n >

example:

Foundry-AR1208/configure/router/rip/timers# flush 300

This example configures the global RIP flush timer to 300 seconds.

related commands:

applicable systems:

All models.

time

Flush timer value in seconds

The range is 1 - 65535; the default is 180.