Configure router rip timers holddown, Parameter description, Configure – Foundry Networks AR3202-CL User Manual

Page 204: Router, Timers, Holddown

Advertising
background image

RIP Configure Commands

June 2004

© 2004 Foundry Networks, Inc.

11 - 23

configure router rip timers holddown

This command configures the global RIP hold down timers.

Hold down time is the interval in seconds during which routing information regarding better routes is suppressed.
This should be configured to be at least twice the value of the update timers.

Parameter

Description

syntax:

[ no ] holddown time < n >

example:

Foundry-140/configure/router/rip/timers# holddown 200

This example configures the global RIP hold down timers to suppress information about routes for 200 seconds.

related commands:

applicable systems:

All models.

time

Holddown timer value in seconds

The range is 1- 65535; the default is 180.

configure router rip timers flush

configure router rip timers update