configure router rip timers update

This command configures the global RIP update timer.

This timer specifies the interval in seconds for sending periodic RIP updates.

Parameter

Description

syntax:

[ no ] update time < n >

example:

Foundry-AR1208/configure/router/rip/timers# update 45

This example globally configures RIP updates to occur every 45 seconds.

related commands:

applicable systems:

All models.

time

Update timer in seconds

The range is 1 - 65536; the default is 120.