Important safety instructions, Replacing the wick filter, Cleaning and maintenance instructions – GE 106763 User Manual

Page 2: How cool mist works, Pre-operating instructions, Operating instructions, Storage instructions, Filter monitor, Figure 2, Filling the water tank

Advertising
background image

When using electrical appliances, basic safety pre-
cautions should always be followed to reduce the
risk of fire, electric shock, and injury to persons,
including the following:

1. Read all instructions before using the appliance.
2. To avoid fire or shock hazard, plug the appliance

directly into a 120 V AC electrical outlet.

3. Keep the cord out of heavy traffic areas. To avoid

fire hazard, NEVER put the cord under rugs, near

heat

registers, radiator, stoves, or heaters.

4. DO NOT place humidifier near heat sources such

as stoves, radiators, and heaters. Do locate your

humidifier on an inside wall near an electrical out-

let. The humidifier should be at least 4" away

from the wall for best results.

5. NEVER place humidifier in an area where it is

accessible to children. NEVER use humidifier in a

closed room,

particularly where a child may be sleeping, resting,

or playing (a closed room may result in excessive

humidity).

6. WARNING: Do not attempt to refill humidifier

without first unplugging the unit from it’s electri-

cal outlet. Failure to heed this warning may cause

personal injury. Be sure to pull the plug and not

the cord.

7. Never place anything over moisture outlet when

the unit is running.

8. NEVER drop or insert any object into any open-

ings.

9. DO NOT operate any appliance with a damaged

cord or plug, after the appliance malfunctions, or

if it has been dropped or damaged in any manner.

Return appliance to manufacturer for examina-

tion, electrical or mechanical adjustment, or

repair.

10. Use appliance only for intended household use as

described in this manual. Any other use not rec-

ommended by the manufacturer may cause fire,

electric shock, or injury to persons. The use of

attachments not recommended may cause hazards.

11. DO NOT use outdoors.
12. Always place humidifier on a firm, flat, level sur-

face. A waterproof mat or pad is recommended for

under the humidifier. NEVER place it on a rug or

carpet, or on a

finished floor that may be damaged by exposure to

water or moisture.

13. DO NOT allow the Moisture Outlet to directly face

the wall. Moisture could cause damage, particular-

ly to wallpaper.

14. Humidifier should be unplugged when not in use.

15. NEVER tilt, move, or attempt to empty unit while

it is operating. Shut off and unplug before remov-

ing the water tank and moving the unit.

16. This humidifier requires daily and weekly mainte-

nance to operate appropriately. Refer to daily and

weekly cleaning procedures.

17. NEVER use detergents, gasoline, glass cleaner, fur-

niture polish, paint thinner, or other household

solvents to clean any part of the humidifier.

18. Excessive humidity in a room can cause water con-

densation on windows and some furniture. If this

happens, turn the humidifier OFF.

19. DO NOT use humidifier in an area where humidi-

ty level is in excess of 50%. Use a hygrometer,

available at your local hardware store, to measure

the humidity.

20. DO NOT attempt to repair or adjust any electrical

or mechanical functions on this unit. Doing so

will void your warranty. The inside of the unit con-

tains no user serviceable parts. All servicing

should be performed by qualified personnel only.

21. Never place housing under water flow or immerse

in

liquids.

22. DO NOT plug in the cord with wet hands: electric

shock could result.

22. DO NOT pour water in any openings other than

the water tank.

PLEASE READ AND

SAVE THESE

IMPORTANT SAFETY

INSTRUCTIONS

Consumer Safety Information

Note: This is an electrical appliance and requires

attention when in use.
Note: If moisture forms on the walls or windows of

the room, turn off the humidifier. The room

already has plenty of humidity and additional

moisture may cause damage.
Note: DO NOT block air grills.
Cord and Plug Installation Safety Instructions
The length of cord used on this appliance was

selected to reduce the hazards of becoming tan-

gled in, or tripping over a longer cord. If a longer

cord is necessary an approved extension cord may

be used. The electrical rating of the extension

cord must be equal to or greater than the rating of

the humidifier. Care must be taken to arrange the

extension cord so that it will not drape over the

countertop or tabletop where it can be pulled on

by children or accidentally tripped over.

THIS PRODUCT IS EQUIPPED WITH A POLARIZED AC

(Alternating Current)PLUG (a plug having one blade

wider than the other). This plug will fit into the power

outlet only one way. If the plug does not fit fully into

the outlet, reverse the plug. If it still does not fit, con-

tact qualified personnel to install the proper outlet.

DO NOT DEFEAT THE SAFETY PURPOSE OF THIS

POLARIZED PLUG IN ANY WAY.

PLEASE READ AND SAVE THESE

IMPORTANT SAFETY INSTRUCTIONS

F E AT U R E S - O P E R AT I O N

R E P L A C I N G T H E F I LT E R C L E A N I N G

I N S T R U C T I O N S - S T O R A G E

REPLACING THE WICK FILTER

Through normal use, waterborne minerals and sedi-

ment become trapped in the Wick Filter. The harder

your water, the greater the amount of minerals in the

water, and the more often you will need to change your

Wick Filter. In general, a brown Wick Filter indicates a

need to replace the Wick Filter.
To replace the Wick Filter, follow the below steps.

1. Turn the Power Knob off and unplug the humidifier

from the

electrical outlet.

2. Remove the Water Tank and Humidifier Housing to

access the Humidifier Base.

3. Discard the old Wick Filter and follow weekly cleaning

instructions.

4. Insert a new Wick Filter into the filter Support in the

Humidifier Base.

5. Replace the Humidifier Housing and then the Water

Tank.

6. Repeat Operating Instruction steps.

It will take about 30 minutes for the humidifier to

reach maximum output.
You can obtain a new Wick Filter by calling 1-877-207-

0923 in the USA or by visiting your nearest retailer or

authorized service center. This humidifier takes model

106763 replacement Wick Filter.

Figure 2

A. Wick Filter

Supports

B. Wick Filter

C. Humidifier

Base

B

C

A

A.Water Tank

B.Carry Handle

C.Humidifier

Housing

D.Power Knob

E. Humidifier Base

F. Filter Support

G. Filter Monitor

H. Humidistat

Knob

I. Tank Cap

A

CLEANING AND MAINTENANCE

INSTRUCTIONS

Humidifiers provide comfort by adding

moisture to dry indoor air. To get the most

benefit from the humidifier and avoid prod-

uct failure, follow all maintenance instruc-

tions carefully. If the recommended care and

maintenance guidelines are not followed,

micro-organisms may be able to grow in the

water within the humidifier.

Daily Maintenance

1. Before cleaning, set the Power Knob to OFF position

and unplug the unit from the electrical outlet.

2. Lift off the Water Tank and Humidifier Housing.

Remove Wick Filter and place in sink or tub as the

Wick Filter will release water when not in the humidifi-

er.

3. Carry the Humidifier Base and the Water Tank to the

sink, then drain and rinse the Humidifier Base and

Water Tank thoroughly to remove any sediment and

dirt. Wipe clean and dry with a clean soft cloth or

paper towel. (DO NOT use metal cleaning utensils or

abrasive cleaners)

4. Put the Wick Filter back in the Filter Support, replace

the Humidifier Housing, then refill the Water Tank

with cool tap water as instructed in filling the Water

Tank instructions.

Weekly Maintenance

Remove scale:

1. Repeat steps 1-3 above.
2. Clean the Humidifier Base by partially filling the

Humidifier Base with one 8-oz cup of undiluted white

vinegar. Let solution stand 20 minutes, clean all interi-

or surfaces with a soft brush.

3. Dampen a cloth with undiluted white vinegar and wipe

out entire Humidifier Base to remove scale.

4. Rinse with clean warm water to remove scale and the

white vinegar solution before beginning to disinfect the

Water Tank.
Disinfect Water Tank:

1. Fill Water Tank with 1/2 teaspoon of chlorine bleach

and 1/2 gallon of water.

2. Let the solution stand for 20 minutes, swishing every

few minutes. Wet all surfaces.

3. Empty the Water Tank after 20 minutes, and rinse well

with water until the bleach smell is gone. Dry with a

clean cloth or paper towel.

4. Refill the Water Tank with cool water; replace the hous-

ing and the Water Tank. Repeat ALL Operating

Instructions.

How COOL Mist works

Your GE Brand Cool Mist humidifier draws dry air

through the rear air intake grill area. This air is then

passed through a moisture–laden Wick Filter, which

retains the minerals and deposits in the water. The

resulting moist air is directed back into the room from

the top air grill.
NOTE: This humidification system provides a cool,

invisible moisture output. It is normal not to see the

mist.
NOTE: The recommended humidity level is between

40%-50%.

PRE-OPERATING INSTRUCTIONS

1. Select a location for your humidifier, on a flat surface,

about 4" away from the wall. Do not place your humid-

ifier on furniture; a floor location that will not be dam-

aged by moisture is best.

2. Be sure the Power Knob is in the OFF position and the

humidifier is disconnected from the electrical outlet.

3. Remove the Water Tank by holding the Carry Handle

and lifting straight upward (see figure 1).

4. Remove the Humidifier Housing by lifting straight

upward. Check to see that the Wick Filter is properly in

place. Replace the Humidifier Housing.

FILLING THE WATER TANK

NOTE: This humidifier holds about 2.6 gallons of

water in the Water Tank and Humidifier Base. The

humidifier will produce up to 4 gallons of mois-

ture over a 24-Hour period, depending on the

room humidity and temperature.

1. Be sure the humidifier Power Knob is turned off and

disconnected from the electrical outlet.

2. Remove the Water Tank from the Humidifier Base by

holding the Carry Handle and lifting straight up (see

figure 1).

3. Twist off the Tank Cap located on the bottom of the

Water Tank by turning counter clockwise and fill the

Water Tank with cool, fresh water.

Do not fill with warm water as this may cause leaking.

4. After filling the Water Tank, replace the tank cap by

firmly turning clockwise and then replace the Water

Tank on the base. The Water Tank will immediately

begin to empty into the Humidifier Base.

5. Plug the power cord into a 120V AC electrical outlet.

OPERATING INSTRUCTIONS

1. Turn the Power Knob to the desired setting (HIGH,

MED or LOW).

2. Turn the Humidistat Knob to the highest setting.
3. When the desired humidity level is reached the

Humidistat Knob can be set to a lower setting to

reduce the humidification rate.
NOTE: Allow up to 30 minutes for the Wick Filter to

fully absorb water and the unit to produce the maxi-

mum moisture output.

4. When the Water Tank is empty and the water in the

Humidifier Base is almost empty, you need to refill the

Water Tank. The fan will continue to run to help dry

the humidifier. Switch off and unplug the unit. Please

follow the Daily Cleaning instructions before refilling

the Water Tank.

5. Refill the Water Tank as directed in the Pre-Operating

Instructions.
IMPORTANT: If you do not plan to use the humidi-
fier for two or more days, make sure any residual
water is drained from the Water Tank, Humidifier
Base and the Wick Filter to prevent algae or bacte-
ria growth.

STORAGE INSTRUCTIONS

If your humidifier will not be in use for two

days or more, or at the end of the season

follow these instructions.

1. Clean and dry the humidifier thoroughly as per the

Weekly Maintenance instructions.

2. Let the humidifier dry completely before storing.

Do not store with water inside the Humidifier Base.

3. Do not store with the Tank cap in place.
4. Throw away the Wick Filter. Do not store with Wick

Filter in place.

5. Store in a cool dry location.

FILTER MONITOR

(Located on the top of the Humidifier Housing) will

let you know when the Wick Filter needs replacing (see

Figure 1).
You will be able to monitor the condition of the Wick

Filter in your humidifier by checking the Filter Monitor

Indicator. When the unit is off or empty of water the

Filter Monitor will read in the OFF/FILL position.

Within 60 minutes of use the Filter Monitor will move

from the OFF position and indicate your Wick Filter

condition. A brand new Wick Filter will register in the

green section reading GOOD filter. After frequent use

of your humidifier, the Filter Monitor indicator will let

you know when the Wick Filter should be changed.

When the needle is in the purple CHANGE section this

means the proper amount of moisture is not getting

into your air due to the large amount of minerals and

sediment that have become trapped in your Wick Filter.

At this point you should replace your Wick Filter. It is

important to change your Wick Filter to get the best

performance from your humidifier.

Figure 1